About MR Configurator2
With MR Configurator2, the servo parameters can be checked if set correctly, and the servo motor and the load-side encoder
can be checked if operated properly.
This section explains the Fully Closed Loop Diagnosis screen.
(c)
(k)
(i)
(j)
(l)
Symbol
Name
(a)
Servo motor-side cumulative
feedback pulses
(after gear)
(b)
Servo motor-side droop
pulses
(c)
Cumulative command pulses
(d)
Load-side encoder cumulative
feedback pulses
(e)
Load-side encoder droop
pulses
(f)
Servo motor-side cumulative
feedback pulses
(before gear)
(g)
Encoder information
(h)
Parameter Setting
(Polarity)
(n)
(m)
(a)
(b)
(d)
(e)
Explanation
The feedback pulses from the servo motor encoder are counted and displayed.
(load-side encoder unit)
When the setting value exceeds 999999999, it starts from 0.
Click "Clear" to reset the value to "0".
In reverse rotation, the value is negative.
Droop pulses of the deviation counter between a servo motor-side position and a command are
displayed.
In reverse rotation, the value is negative.
Position command input pulses are counted and displayed.
Click "Clear" to reset the value to "0".
Under reverse command, the value is negative.
The feedback pulses from the load-side encoder are counted and displayed.
When the setting value exceeds 999999999, it starts from 0.
Click "Clear" to reset the value to "0".
In reverse rotation, the value is negative.
Droop pulses of the deviation counter between a load-side position and a command are displayed.
In reverse rotation, the value is negative.
The feedback pulses from the servo motor encoder are counted and displayed.
(Servo motor encoder unit)
When the setting value exceeds 999999999, it starts from 0.
Click "Clear" to reset the value to "0".
In reverse rotation, the value is negative.
The load-side encoder information is displayed.
The display contents differ depending on the load-side encoder type.
• ID: The ID No. of the load-side encoder is displayed.
• Data 1: For an incremental type linear encoder, the counter from powering on is displayed. For an
absolute position type linear encoder, absolute position data is displayed.
• Data 2: For the incremental type linear encoder, the distance (number of pulses) from the reference
mark (Z-phase) is displayed. For the absolute position type linear encoder, "00000000" is displayed.
"+" is displayed for the address increasing direction in the servo motor CCW direction, and "-" is
displayed for the address decreasing direction in the servo motor CCW direction.
(f)
(g)
(h)
12 USING A FULLY CLOSED LOOP SYSTEM
12.5 Basic functions
12
Unit
pulse
pulse
pulse
pulse
pulse
pulse
435