■Dedicated stand-alone reactor
Pair the applicable FR-XC multifunction regeneration converter with the appropriate dedicated stand-alone reactor as shown
in the table below.
Multifunction regeneration converter
FR-XC-7.5K
FR-XC-11K
FR-XC-15K
FR-XC-22K
FR-XC-30K
FR-XC-37K
FR-XC-55K
FR-XC-H7.5K
FR-XC-H11K
FR-XC-H15K
FR-XC-H22K
FR-XC-H30K
FR-XC-H37K
FR-XC-H55K
Selection example
The following information explains how to select a multifunction regeneration converter to connect to the servo amplifiers
listed below.
Servo amplifier
MR-J5-500G
MR-J5-350G
MR-J5-700G
6 OPTIONS AND PERIPHERAL EQUIPMENT
184
6.4 FR-XC multifunction regeneration converter
Number of units
1
1
2
Dedicated stand-alone reactor
FR-XCL-7.5K
FR-XCL-11K
FR-XCL-15K
FR-XCL-22K
FR-XCL-30K
FR-XCL-37K
FR-XCL-55K
FR-XCL-H7.5K
FR-XCL-H11K
FR-XCL-H15K
FR-XCL-H22K
FR-XCL-H30K
FR-XCL-H37K
FR-XCL-H55K
Servo motor
HK-ST502W
HK-ST352W
HK-ST702W
Number of units
1
1
2