6.4

Test Function

The RFID interface module has two operation mode: RUN mode and TEST mode.
• RUN mode is used when the programmable controller is running. In RUN mode, all commands can be used.
• TEST mode is used at the time of RFID system installation, maintenance, and troubleshooting.

How to switch the operation mode

This section describes how to switch the operation mode.
Switching using programs
When TEST mode execution request (Y15) is turned on, the operation mode changes to TEST mode. When TEST mode
execution request (Y15) is turned off, the operation mode changes to RUN mode. ( Page 125 TEST mode execution
request (Y15))
• This method is available for use only when "Enable" is set to "Enable channel 1 TEST mode", "Enable
channel 2 TEST mode (ER-1V680D2 use)" and "Enable Y contact test request" on the unit parameters. The
channels that "Enable" is not set to "Enable channel 1 TEST mode" and "Enable channel 2 TEST mode
(ER-1V680D2 use)" do not start TEST mode. ( Page 34 Basic Setting)
• Before switching to TEST mode, set the buffer memory (Un\G8000 to Un\G8002). If the buffer memory
(Un\G8000 to Un\G8002) is changed after switching to TEST mode, the test execution details cannot be
changed. ( Page 132 TEST mode)
Ex.
Program to switch to TEST mode when M0 turns on and to RUN mode when M5 turns on
Switching using module parameters
Set "TEST mode" to "Operation mode" of module parameter to write to the CPU module, and reset the CPU module or power
off and on. ( Page 34 Basic Setting)
6 FUNCTIONS
78
6.4 Test Function

Advertisement

Table of Contents
loading

This manual is also suitable for:

Er-1v680d2

Table of Contents