Communication test using module parameters
This section describes the communication test method.
1.
Setting of module parameters
[007ER-1V680D1] or [007ER-1V680D2]  [Module Parameter]  [Basic Setting]
Set "TEST mode (Communication test)" to "Operation mode".
Check that "Enable" is set to "Enable channel 1 TEST mode" and "Enable channel 2 TEST mode (ER-1V680D2 use)".
2.
Writing data to the CPU module
To switch to TEST mode, write the data to the CPU module and reset the CPU module or power off and on.
3.
Check of test results
The test results are stored in Processing result monitor storage area (Un\G42, Un\G4042). ( Page 80 Test results)
Test results
Processing result monitor storage area
CH1
Un\G42
The test results can be checked with the operation indication lamps of amplifier. For details, refer to the
manuals for the amplifier to use.
6 FUNCTIONS
80
6.4 Test Function
Data format
CH2
Un\G4042
■When completed successfully (processing time)
0000 to 9999 [BCD] (in units of 10ms)
■When completed with an error (E0 + error code)
E070H: Tag communication error
E072H: Tag not present error
E079H: ID system error 1
E07AH: Address error
E07CH: Antenna error