Mitsubishi Electric ER-1V680D1 User Manual page 51

Rfid interface module, melsec iq-r series recognized
Table of Contents

Advertisement

Ex.
When executing the Clear bit command to the data of three bytes starting from the address 0010H in the data storage order
0001H (Lower  Upper)
Stored data in
the buffer memory
b15
Un\G100
2468H
Un\G101
1357H
b7
Data before execution
0
0
0
1
0
Stored data
0
1
1
0
1
Data after execution
0
0
0
1
0
Data before execution are held.
Bits are cleared.
RF tag before
execution
b0
b7
0010H
0011H
0012H
0013H
b0
b7
b0
b7
0
1
0
0
0
1
1
0
1
0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
0
1
0
0
0
0
1
0
0
0
0
0
b0
b7
12H
0010H
34H
0011H
56H
0012H
78H
0013H
b0
1
0
1
0
1
1
0
1234H 56H
1
0
1
0
1
1
1
6824H 57H
1210H 00H
0
0
0
0
0
0
0
RF tag after
execution
b0
12H
10H
00H
78H
6 FUNCTIONS
6.2 Command
6
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Er-1v680d2

Table of Contents