4
INSTALLATION AND WIRING
This chapter describes installation and wiring of RFID interface module.
4.1
Installation of RFID Interface Module
For details, refer to the following.
MELSEC iQ-R Module Configuration Manual
Consider sufficiently operability, maintainability, and environmental resistance before installing the RFID interface module and
programmable controller in a control panel. Use the RFID interface module indoors.
Precautions
• Do not drop the case or expose the case to strong impact. Doing so can cause failure or malfunction.
• Prevent foreign matter such as dust or wire chips from entering the RFID interface module. Doing so can cause fire, failure,
or malfunction.
• An incorrectly mounted RFID interface module results in the risk of malfunction, failure, and dropping. When used in an
environment of high oscillation, secure the RFID interface module with screws.
• Do not touch the conductive parts and electronic components while the module is powered. Doing so can cause
malfunction or electric shock.
• Before installing or removing the module, shut off all phases of the external power supply. Failure to do so can cause
product damage.
• Before cleaning the module or tightening the module fixing screws or connector screws for external power supply, shut off
all phases of the external power supply. Failure to do so can cause the module failure or malfunction. Undertightening can
cause drop, short-circuit, or malfunction of the module. Overtightening can damage the screws and/or module, resulting in
drop, short-circuit, or malfunction of the module.
4 INSTALLATION AND WIRING
24
4.1 Installation of RFID Interface Module