False Operation Panel Command Type; State Transition Information Function; Command Receive Confirmation Function - Mitsubishi Electric DX-NT400E Operation Manual

Digital recorder rs-232c communication capacity
Hide thumbs Also See for DX-NT400E:
Table of Contents

Advertisement

Command codes (continued)
o False operation panel command type
This system is used to specify operations of this unit from a PC as if operating the actual operation button of the remote
control while viewing the output video. Each command corresponds to the operation button of the remote control.
• Input confirmation type
Send commands as if operate the buttons of the remote control. As a general rule, do not send commands continuously,
but send the next command after checking that the present command has been executed and completed. After sending
a command, the command execution result, error type, and command name can be checked by the status returned from
the unit. To check the actual execution, view the output screen of the unit on the monitor screen.
Example) Playing back the recorded data using still-frames.
Command
Replied status code
from unit to PC
from PC
KKP0
#1
RC
#2
EX,00KKP0
KKB1
#1
PC
#2
EX,00KKB1
KKB4
#1
PC
#2
EX,00KKB4
For control type commands such as recording, playback, etc., the interval between command transmission
and the actual operation (command execution) may take some time. To prevent the gap between operation and
actual execution, read the status after sending the command and check the transition of the actual execution.
o State transition information function
Example) Issuing state transition information of system mode "POWER ON".
Replied status code
from unit to PC
EX,AA,0103
#2
When setting "MODE" in the <RS-232C> screen to "REMOTE A", every state information is returned from the unit. When
setting to "REMOTE B", state transition information is returned from the unit. When setting to "REMOTE C", state
information is not returned from the unit.
o Command receive confirmation function
After executing a received command, the error type during command execution is notified after execution status "EX".
Contents of Error
Error type
00
Normal
01
Execution Error
02
Execution Unable Error
03
Incorrect command
04
Incorrect parameter
05
Executing the command
06
Not used
Indicates that a command equivalent to "press the POWER button" was sent.
Indicates that the unit has received a command.
EX
: Indicates that a command has been executed.
#2
00
: Indicates that the execution was successful.
KKP0 : Indicates that the POWER button was operated.
Indicates that a command equivalent to "press the PLAY button" was sent.
Indicates that the unit has received a command.
EX
: Indicates that a command has been executed.
#2
00
: Indicates that the execution was successful.
KKB1 : Indicates that the PLAY button was operated.
Indicates that a command equivalent to "press the PAUSE button" was sent.
Indicates that the unit has received a command.
EX
: Indicates that a command has been executed.
#2
00
: Indicates that the execution was successful.
KKB4 : Indicates that the PAUSE button was operated.
Meaning
EX
: Indicates that a command has been executed.
AA
: Indicates the state transition information.
0103 : Indicates that status condition of POWER ON.
Meaning
4

Advertisement