smr2005-058-007_a
– If any result is out of specification, replace sta-
tor.
– Replug connectors properly.
Insulation
– Disconnect the magneto wiring harness con-
nector.
smr2005-058-006_a
– Install the 4-pin magneto harness adapter
(P/N 295 000 131) to the magneto wiring har-
ness.
– IMPORTANT: Leave wiring harness side dis-
connected.
smr2005-058
smr2005-058-008_a
1. Do not plug these connectors
– Set multimeter to
– Connect multimeter between YELLOW wires.
Any YELLOW wire and
– Read resistance.
– If there is a resistance or continuity, the stator
coils and/or the wiring is grounded and needs
to be repaired or replaced.
Replug connectors properly.
Dynamic Test
AC Voltage Test
– Disconnect the voltage regulator/rectifier con-
nectors.
www.SeaDooManuals.net
Section 07 ELECTRICAL SYSTEM
Subsection 02 (CHARGING SYSTEM)
.
TERMINAL
infinity (open circuit)
engine ground
RESISTANCE @
20°C (69°F)
173