Target Address (Text Field) Enter the IP or IPX address of the device to
poll.
Round Trip Time (Read-only) This is the interval in milliseconds
between the time the last frame was sent to the target device and the
time a response was received by the Module. If there is no response
within a few seconds, no reply is shown. Also displayed will be the
number of router hops and, if set, the time-to-live for the frame.
The Module can be configured to automatically poll several devices at
regular intervals, and report back to a management station if there is
no response. This facility is only available through SNMP management.
Status
The Status screen provides read-only information about the Module. To
display the screen, select the STATUS button on the Main Menu screen.
Figure 3-25 Status Screen
System Up Time (seconds) This field indicates how long the unit has
been running since the last reset. See
description of resetting the unit.
Number of Resets This field shows the total number of system resets
since the Module was first installed, or initialized. This information may
DUA1663-0BAA03
3Com SuperStack II Status
System Up Time (seconds):
Number of Resets:
Last Reset Type:
Version Numbers
Hardware Version:
Upgradable Software Version:
Boot Software Version:
FAULT LOG
456
1
Command
2.00
3.00
1.00
CANCEL
"Reset"
on page 3-48 for a
Status
3-45