Table E-2 Alarm Actions
Action
No action.
Notify only.
Notify and
blip port.
Notify and disable
port.
Notify and enable
port.
Blip port.
Disable port.
Enable port.
Notify and switch
resilient port.
Notify and
blip module.
Notify and disable
module.
Notify and enable
module.
Blip module.
Disable module.
Re-enable module.
A
M
AND
DVANCED
ANAGEMENT
High Threshold
Send Trap.
Send Trap. Turn port off. Turn
port on after 5 seconds.
Send Trap. Turn port off.
Turn port off. Turn port on
after 5 seconds.
Turn port off.
Send Trap. If port is the Main
of a resilient pair then switch
to standby.
Send Trap. Turn all ports on
module off. Turn ports back to
original state after 5 seconds.
Send trap. Turn all ports on
module off.
Turn all ports on module off.
Low Threshold
Send Trap. Turn port on.
Turn port on.
Send Trap. Turn ports
back to original state.
Turn all ports on module
off. Turn ports back to
original state after 5
seconds.
Turn ports back to
original state.