Falling Threshold
Falling Event
Alarm Type
3) Enter the owner name, and set the status of the entry. Click Apply.
Interval (seconds)
Owner
Status
5.2 Using the CLI
5.2.1 Configuring Statistics
Step 1
Set the falling threshold of the variable. Valid values are from 1 to
2147483647. When the sampling value or the difference value is below the
threshold, the system will trigger the corresponding Falling Event.
Note:
The falling threshold should be less than the rising threshold.
Specify the index of the Event entry that will be triggered when the sampling
value or the difference value is below the preset threshold. The Event entry
specified here should be enabled first.
Specify the alarm type for the entry.
Rising: The alarm is triggered only when the sampling value or the difference
value exceeds the rising threshold.
Falling: The alarm is triggered only when the sampling value or the difference
value is below the falling threshold.
All: The alarm is triggered when the sampling value or the difference value
exceeds the rising threshold or is below the falling threshold.
Set the sampling interval. Valid values are from 10 to 3600 seconds.
Enter the owner name of the entry with 1 to 16 characters.
Enable or disable the entry.
Enable: The entry is enabled.
Disable: The entry is disabled.
configure
Enter Global Configuration Mode.
RMON Configurations
User Guide