Kikusui BIM1000 Series User Manual page 72

Battery impedance meter
Table of Contents

Advertisement

Remote Control | Message Reference
 Continuous measurement
The product performs continuous measurement and trigger wait even when :INITiate or READ? is not
sent.
Program header
Value
Response
Note
 Trigger wait
Switches from the idle state to the trigger wait state.
Program header
Note
 Trigger source
Selects whether to use the internal signal or an external signal for triggering.
Program header
Value
Response
 Turning the delay on or off
Sets whether a delay will be inserted from when a trigger is detected until the measurement starts.
Program header
Value
Response
 Delay
Sets the delay when :TRIGger:DELay:STATe is set to on.
Program header
Value/Response
Unit
72
User's Manual
:INITiate:CONTinuous
:INITiate:CONTinuous?
{1|0|ON|OFF}
{ON|OFF}
This is automatically set to on when the power is turned on or when the product changes
to local mode.
:INITiate[:IMMediate]
When continuous measurement (:INIT:CONT) is on, an execution error occurs.
:TRIGger:SOURce
:TRIGger:SOURce?
{INTernal|EXTernal}
INTernal:
Uses the internal signal for triggering.
EXTernal:
Uses the SIGNAL I/O TRIG-IN signal, *TRG, or the SNGL TRG key on
the front panel for triggering.
{INTERNAL|EXTERNAL}
:TRIGger:DELay:STATe
:TRIGger:DELay:STATe?
{1|0|ON|OFF}
{ON|OFF}
:TRIGger:DELay
:TRIGger:DELay?
<0 to 9.999 (NR2)>
Seconds