Kikusui BIM1000 Series User Manual page 56

Battery impedance meter
Table of Contents

Advertisement

Remote Control | List of Messages
Queries the QUEStionable status register
Program header
:STATus:QUEStionable[:EVENt]?
:STATus:QUEStionable:CONDition?
:STATus:QUEStionable:ENABle
:STATus:QUEStionable:ENABle?
*1.
Response data for queries
Measurement function
Program header
:FUNCtion
:FUNCtion?
:RESistance:RANGe
:RESistance:RANGe?
:VOLTage:RANGe
:VOLTage:RANGe?
:AUTorange
:AUTorange?
:ADJust?
:ADJust:CLEAr
:SAMPle:RATE
:SAMPle:RATE?
:SENSe:AVERage:STATe
:SENSe:AVERage:STATe?
:SENSe:AVERage
:SENSe:AVERage?
*1.
Response data for queries
Judgment function
Program header
:SENSe:JUDGment:STATe
:SENSe:JUDGment:STATe?
:SENSe:JUDGment:RESistance:STATe
:SENSe:JUDGment:RESistance:STATe?
:SENSe:JUDGment:VOLTage:STATe
:SENSe:JUDGment:VOLTage:STATe?
:SENSe:JUDGment:RESistance:UPPer
56
User's Manual
Description
*1
Parameter
0 to 3845
Queries the event of the QUEStionable status register.
A query clears the contents of the register.
0 to 3845
Queries the condition of the QUEStionable status regis-
ter. A query does not clear the contents of the register.
0 to 3845
Sets the QUEStionable status enable register
0 to 3845
Queries the QUEStionable status enable register
*1
Parameter
RV|RESistance|VOLTage
RV|RESISTANCE|VOLTAGE
0 to 3.1
3.000E-3 to 3.0000E+0
0 to 1050
6.00000E+0 to 1.00000E+3
1|0|ON|OFF|RESistance|VOLTage Sets the auto measurement range
ON|OFF|RESISTANCE|VOLTAGE Queries the auto measurement range
0|1
FAST|MEDium|SLOW
FAST|MEDIUM|SLOW
1|0|ON|OFF
ON|OFF
2 to 99
2 to 99
*1
Parameter
1|0|ON|OFF
ON|OFF
BOTH|OFF|UPPer|LOWer
BOTH|OFF|UPPER|LOWER Queries the resistance judgment
BOTH|OFF|UPPer|LOWer
BOTH|OFF|UPPER|LOWER Queries the voltage judgment function
<NR2>
Description
Sets the measured value that is shown on
the front panel
Queries the measured value that is shown
on the front panel
Sets the resistance measurement range
Queries the resistance measurement range
Sets the voltage measurement range
Queries the voltage measurement range
Executes zero adjustment and queries the
result
Clears zero adjustment
Sets the sampling speed
Queries the sampling speed
Sets the average function
Queries the average function
Sets the average count
Queries the average count
Description
Sets the judgment function
Queries the judgment function
Sets the resistance judgment function
function
Sets the voltage judgment function
Sets the upper resistance judgment
limit
BIM1000 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bim1030Bim1100

Table of Contents