Installing The Left Control Panel - Dell EMC PowerEdge R240 Installation And Service Manual

Hide thumbs Also See for PowerEdge R240:
Table of Contents

Advertisement

Figure 75. Removing the left control panel
Next steps
1.
Install the left control

Installing the left control panel

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the front
bezel.
4.
Remove the air
shroud.
Steps
1. Route the control panel cable through the side and the guide slots in the system.
NOTE:
Route the cable properly to prevent the cable from being pinched or crimped.
2. Align and insert the left control panel assembly in the slot on the system.
3. Connect the control panel cable to the system board connector.
4. Using the appropriate screwdriver, replace the screws that secure the left control panel assembly to the system.
76
Installing and removing system components
panel.
Safety
Before working inside your
instructions.
system.

Advertisement

Table of Contents
loading

Table of Contents