Gree GMV5E Series Service Manual page 10

Dc inverter vrf units
Table of Contents

Advertisement

GREE
No
Name
12
Heat exchanger
13
Fan
Defrosting temperature
14
sensor
Electronic expansion
15
valve for heating
16
One-way valve
Subcooler electronic
17
expansion valve
18
Subcooler
Liquid outlet temperature
19
sensor of subcooler
Inlet temperature sensor
20
of gas-liquid separator
Gas outlet temperature
21
sensor of subcooler
22
Low-pressure sensor
23
Gas-liquid separator
Outlet temperature
24
sensor of gas-liquid
separator
25
Oil equalizing valve 1
26
One-way valve
27
Unloading valve
28
Oil equalizing valve 2
29
Filter
30
Capillary tube
31
Liquid valve
32
Air valve
Low-pressure
33
measurement valve
34
Oil balance valve
35
Oil check valve
36
Unloading valve
37
Air by-pass valve
38
Pressure-balanced valve
GMV5E DC INVERTER VRF UNITS SERVICE MANUAL
Used for outdoor heat exchange.
Strengthens heat exchanging.
Used for defrosting detection.
Controls refrigerant adjustment in heating mode.
Controls refrigerant flow direction.
Controls the degree of subcooling of tube refrigerant when the system is running in
cooling mode, and reduces the capacity loss on pipes.
Controls the degree of subcooling of tube.
Detects tube temperature.
Detects the inlet temperature of gas-liquid separator to prevent the system from
running when the refrigerant flows back to the compressor.
Detects gas temperature of subcooler.
Detects system low pressure to avoid extra-low operating pressure.
Separate gas and liquid to prevent the system from running when the refrigerant
flows back to the compressor.
Detects internal status of gas-liquid separator to further control the compressor
suction performance.
Used for oil equalizing control among modules.
Used for oil equalizing control among modules and avoid reverse flow of oil.
Avoids over-high pressure caused by pipeline blind spot.
Used for oil equalizing control among modules.
Prevents impurities from entering components and parts.
Supports flow regulating and pressure reduction.
Stop valve, closed when the unit is delivered from the factory and will be opened
after installation.
Stop valve, closed when the unit is delivered from the factory and will be opened
after installation.
Detects the low pressure value or charges refrigerant during system running.
Stop valve, closed when the unit is delivered from the factory and will be opened
after installation.
Checks the quality of refrigerating machine oil of compressor during maintenance.
Avoid over-high pressure caused by pipeline blind spot.
Avoids extra-high or low operating pressure.
Ensures success startup of compressor.
6
Main Function