Gree GMV-ND100L/A-T Service Manual

Gree GMV-ND100L/A-T Service Manual

Multi vrf-ii indoor unit
Hide thumbs Also See for GMV-ND100L/A-T:
Table of Contents

Advertisement

MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL
EUROPEAN/LATIN AMETICA (R410A)

Advertisement

Table of Contents
loading

Summary of Contents for Gree GMV-ND100L/A-T

  • Page 1 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A)
  • Page 2: Table Of Contents

    CONTENTS PRODUCT ..................................2 1 PRODUCT LIST ............................2 1.1 Floor Standing Type ............................2 1.2 High Static Pressure Duct Type ........................2 1.3 Low Static Pressure Duct Type ........................3 1.4 4-way Cassette ..............................3 1.5 Compact 4-way Cassette ..........................4 1.6 2-way Cassette ..............................
  • Page 3 3.1 Installation of Floor Standing indoor unit ..................... 75 3.2 Installation of High Static Pressure Duct Type unit ..................77 3.3 Installation of Low Static Pressure Duct Type unit ..................80 3.4 Installation of 4-way Cassette Type unit ...................... 83 3.5 Installation of Compact 4-way Cassette Type unit ..................
  • Page 4 5.9 Fresh air Processing Unit..........................191 5.10 Slim Duct Type ............................198 5.11 Air Handler type Indoor Unit ........................202 5.12 Console Type Indoor Unit .......................... 206 5.13 Wall Mounted type Indoor Unit ........................208 5.14 Super High Static Pressure Duct Type Indoor Unit ................213...
  • Page 5 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) PRODUCT...
  • Page 6: Product

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) PRODUCT 1 Product List 1.1 Floor Standing Type Cooling Heating Capacit Capacity Appearance Model Product Code Power Supply Refrigerant GMV-ND100L/A- CM300N0060 10.0 11.0 220- 240V~50Hz R410A 208- 230V~60Hz GMV-ND140L/A- CM300N0070 14.0 15.0 1.2 High Static Pressure Duct Type Cooling...
  • Page 7: Low Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 1.3 Low Static Pressure Duct Type Cooling Heating Power Capacity Capacity Appearance Model Product Code Refrigerant Supply GMV- CM800N3370 ND22PLS/A-T GMV- CM800N3380 ND25PLS/A-T GMV- CM800N3490 ND28PLS/A-T GMV- CM800N3390 ND32PLS/A-T GMV- CM800N3500 ND36PLS/A-T GMV- CM800N3400...
  • Page 8: Compact 4-Way Cassette

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 1.5 Compact 4-way Cassette Cooling Heating Power Capacity Capacity Appearance Model Product Code Refrigerant Supply GMV-ND22T/B-T CM500N0610 220- GMV-ND28T/B-T CM500N0620 240V~ GMV-ND36T/B-T CM500N0630 50Hz R410A GMV-ND45T/B-T CM500N0640 208- 230V~ GMV-ND50T/B-T CM500N0600 60Hz GMV-ND56T/B-T CM500N0650...
  • Page 9: Fresh Air Processing

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 1.9 Fresh air Processing Cooling Heating Product Power Capacity Capacity Appearance Model Refrigerant Code Supply 220- GMV- CM800N3 14.0 10.0 240V/1~ NX140P/A(X1.2)-K 50Hz GMV- CM800N3 22.4 16.0 NX224P/A(X2.0) -M GMV- CM800N3 380- 28.0 20.0...
  • Page 10: Console Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 1.12 Console Type Indoor Unit Cooling Heating Power Refrige Capacity Capacity Appearance Model Product Code Supply rant GMV-ND22C/A-T CM400N0140 220- 240V~ GMV-ND28C/A-T CM400N0070 50Hz GMV-ND36C/A-T CM400N0080 R410A 208- GMV-ND45C/A-T CM400N0150 230V~ GMV-ND50C/A-T CM400N0090 60Hz...
  • Page 11 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-N71G/A4A- CM100N1600 GMV-N22G/A8A- CM100N1770 GMV-N28G/A8A- CM100N1780 GMV-N36G/A8A- CM100N1790 208- GMV-N45G/A8A- 230V~ CM100N1800 60Hz GMV-N50G/A8A- CM100N1810 GMV-N56G/A8A- CM100N1820 GMV-N63G/A8A- CM100N1830 Cooling Heating Power Refrige Capacity Capacity Appearance Model Product Code Supply rant GMV-N71G/A8A- CM100N1840 GMV-N22G/C9A-...
  • Page 12 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-N56G/A3A-D CM100N1460 GMV-N63G/A3A-D CM100N1470 GMV-N71G/A3A-D CM100N1420 GMV-N22G/A2A-D CM100N1930 GMV-N28G/A2A-D CM100N1940 GMV-N36G/A2A-D CM100N1950 208- GMV-N45G/A2A-D CM100N1960 230V~ GMV-N50G/A2A-D CM100N1970 60Hz GMV-N56G/A2A-D CM100N1980 GMV-N63G/A2A-D CM100N1990 GMV-N71G/A2A-D CM100N2000 Cooling Heating Power Refrige Appearance Model Product Code Capacity Capacity...
  • Page 13: Super High Static Pressure Duct Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-N63G/E3A-D CM100N2310 GMV-N71G/E3A-D CM100N2320 1.14 Super High Static Pressure Duct Type Indoor Unit Cooling Heating Refri Power Capacity Capacity Model Product Code gera Appearance Supply GMV-ND22PHS/B-T CM810N0300 GMV-ND25PHS/B-T CM810N0310 GMV-ND28PHS/B-T CM810N0320 GMV-ND32PHS/B-T CM810N0330 GMV-ND36PHS/B-T...
  • Page 14: Nomenclature

    □ □ □ □ Description Options Product code GMV-Gree Multi VRF Units indoor unit code indoor unit -N D – DC motor Motor type NULL – AC motor R – pure heat pump/ all heat exchanger with cooling function L-cooling only unit...
  • Page 15: Specifications

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3 Specifications 3.1 Floor Standing Type Model GMV-ND100L/A-T GMV-ND140L/A-T Cooling capacity 10.0 14.0 Heating capacity 11.0 15.0 Circulating air volume m3/h 1850 1850 Noise dB(A) 220-240V~50Hz 220-240V~50Hz Power supply 208-230V~60Hz 208-230V~60Hz...
  • Page 16: High Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.2 High Static Pressure Duct Type GMV- GMV- GMV- GMV- GMV-ND80 GMV-ND90 Model ND56PHS/A ND63PHS/ ND71PHS/A ND100PHS/ PHS/A-T PHS/A-T Horse Power Cooling capacity 10.0 Heating capacity 10.0 11.2 Air volume 1000 1000 1100 1100...
  • Page 17: Low Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Notes: ① Rated cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units. ② Rated heating capacity test conditions: indoor 20° C DB, outdoor 7° C DB/6 ° C WB; connection pipe length: 5 m, without height drop between units.
  • Page 18 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV- GMV- GMV- GMV- GMV- GMV- GMV- GMV- Model ND63PLS/ ND71PLS/ ND80PLS/ ND90PLS/ ND100PL ND112PL ND125PL ND140PL S/A-T S/A-T S/A-T S/A-T Horse Power Cooling 10.0 11.2 12.5 14.0 capacity Heating 10.0 11.2 12.5 14.0...
  • Page 19: 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.4 4-way Cassette Type GMV- GMV- GMV- GMV- GMV- GMV- GMV- Model ND28T ND36T/ ND45T/ ND50T/A ND56T/ ND63T/ ND71T/A /A-T Horse Power Cooling capacity Heating capacity Air volume 1000 1000 1180 Cooling power input Cooling current input Heating power input...
  • Page 20: Compact 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Panel 950× 950× 950× 950×950 950×950 950×950 1040× W×D×H dimensions 950×65 950×65 950×65 ×65 ×65 ×65 1040×65 Main 26.5 32.5 32.5 32.5 32.5 32.5 46.5 body Net weight Panel Notes: ① Rated cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units.
  • Page 21: 2-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Panel W×D× 670×670 670×670×5 670×670×5 670×670×5 670×670×5 670×670×5 dimensions ×50 Main 20.5 20.5 20.5 20.5 20.5 20.5 body Net weight Panel Notes: ① Rated cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units.
  • Page 22: 1-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Notes: ① Rated cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units. ② Rated heating capacity test conditions: indoor 20° C DB, outdoor 7° C DB/6 ° C WB; connection pipe length: 5 m, without height drop between units.
  • Page 23: Floor Ceiling Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.8 Floor Ceiling Type GMV- GMV- GMV- GMV- GMV- Model ND28ZD/A- ND36ZD/A- ND50ZD/ ND63ZD/ ND71ZD/A-T Horse Power Cooling capacity Heating capacity Air volume 1400 1400 Cooling power input Cooling current input 0.25 0.38 0.38...
  • Page 24: Fresh Air Processing Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) External Φ17×1.75 Φ17×1.75 Φ17×1.75 Φ17×1.75 Drain pipe diameter × thickness 1420×700×2 Dimensions W×D×H 1700×700×245 1700×700×245 1700×700×245 Net weight Notes: ①. Rated Cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units.
  • Page 25 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Net weight 63.5 Notes: ①. a.Rated cooling capacity test conditions: fresh air inlet 35° C DB/28° C WB; connection pipe length: 5 m, without height drop between units; The default air outlet temperature of the unit is 18°...
  • Page 26: Slim Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3 dB(A) on this value. The noise in the lowest speed may decrease by about 5 dB(A) on this value. The recorded noise value of the sample unit is tested in semi-anechoic room. Under actual installation, the noise value is usually higher than the recorded value of the sample due to the influence of ambient noise and reflected sound.
  • Page 27: Air Handler Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Heating current input *Minimum line current 0.38 0.38 0.38 0.38 0.63 *Maximum fuse current Sound pressure level dB(A) Power supply 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Liquid pipe Piping interface...
  • Page 28: Console Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) *Maximum fuse current dB(A Sound pressure level Power supply* 208-230V 1 phase ~60Hz Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Liquid pipe Piping interface Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Gas pipe External Φ19×2.5 Φ19×2.5 Φ19×2.5 Φ19×2.5...
  • Page 29 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) External Φ17.2×1. Φ17.2×1.0 Φ17.2×1.0 Φ17.2×1.0 Φ17.2×1.0 Drain pipe diameter × thickness 700×215×6 700×215×60 700×215 700×215× 700×215×60 Dimensions W×D×H ×600 Net weight Notes: ①. a.Rated Cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units ②.
  • Page 30: Wall Mounted Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.13 Wall Mounted type Indoor Unit GMV- GMV- GMV- GMV- GMV- Model N22G/A3A-K N28G/A3A-K N36G/A3A-K N45G/A3A-K N50G/A3A-K Horse Power Cooling capacity Heating capacity Air volume Cooling power input Cooling current input 0.31 0.31 0.31...
  • Page 31 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV- GMV- GMV- GMV- GMV- Model N22G/A2A-K N28G/A2A-K N36G/A2A-K N45G/A2A-K N50G/A2A-K Horse Power Cooling capacity Heating capacity Air volume Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31 0.31...
  • Page 32 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV- GMV- GMV- GMV- GMV- Model N22G/A4A-K N28G/A4A-K N36G/A4A-K N45G/A4A-K N50G/A4A-K Horse Power Cooling capacity Heating capacity Air volume Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31 0.31...
  • Page 33 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV- GMV- GMV- GMV- GMV- Model N22G/A8A-K N28G/A8A-K N36G/A8A-K N45G/A8A-K N50G/A8A-K Horse Power Cooling capacity Heating capacity Air volume Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31 0.31...
  • Page 34 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Heating capacity Air volume Cooling power input Cooling current input 0.31 0.31 0.31 Heating power input Heating current input 0.31 0.31 0.31 *Minimum line current 0.25 0.25 0.38 0.38 0.38 *Maximum fuse current Sound pressure level dB(A)
  • Page 35 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) *Maximum fuse current Sound pressure level dB(A) Power supply 220-240V 1 phase ~50Hz Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Liquid pipe Piping interface Φ9.52 Φ9.52 Φ12.7 Φ12.7 Φ12.7 Gas pipe External Drain Φ20×1.5 Φ20×1.5 Φ20×1.5...
  • Page 36: Super High Static Pressure Duct Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.14 Super High Static Pressure Duct Type Indoor Unit GMV- GMV- GMV- GMV- GMV- GMV- Model ND22PHS/B ND25PHS/B ND28PHS/B ND32PHS/B ND36PHS/B ND40PHS/B Horse Power Cooling capacity Heating capacity Air Volume External Static 60/0~150 60/0~150...
  • Page 37 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Heating power input Heating current input *Minimum line current *Maximum fuse current Sound dB(A) pressure level Power supply** 220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz Liquid Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Pipe pipe...
  • Page 38 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) thickne Dimen W×D× 700×300×1 700×300×1 700×300×1 700×300×1 700×300×1 700×300×1 sions Net weight Notes: ① Rated cooling capacity test conditions: indoor 27° C DB/19° C WB, outdoor 35° C DB; connection pipe length: 5 m, without height drop between units. ②...
  • Page 39 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) CONTROL...
  • Page 40: Control

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) CONTROL 1 Operation Flowchart...
  • Page 41: Wired Controller

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 2 Wired Controller 2.1 Control panel Fig.2.1 Appearance of wired controller Fig2.2 LED graphics of wired controller Table 2.1 LED display instruction Symbols Instructions Up and down swing function Left and right swing function It's valid under Save mode and displays during setting process.
  • Page 42 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Auto mode (Under Auto mode, the indoor units will automatically select their operating mode as per the temperature change so as to make the ambient comfortable.) It shows the setting temperature value(In case the wired controller is controlling a Fresh Air Indoor Unit, then the temperature zone will display FAP) Cooling mode...
  • Page 43: Installation And Removal

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Gate-control function Shielding status Child Lock status One wired controller controls multiple indoor units Save status of indoor unit It indicates the current wired controller is the slave wired controller (address of wired controller is 02) Memory status (The indoor unit resumes the original setting state after power failure and then power recovery)
  • Page 44 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 2.2.2 Installation method Fig.2.5 Installation of Wired Controller Above is a simple installation method of wired controller. Please pay attention to the following: ◆ Before installation, disconnect power of the indoor unit. Do not operate when power is connected. ◆...
  • Page 45 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 2.2.4 Connection of communication cord There are 4 ways to connect wired controller with indoor units’ network: Fig.2.7 One wired controller controls Fig.2.8Two wired controllers one indoor unit control one indoor unit Fig.2.9 One wired controller controls multiple indoor units simultaneously.
  • Page 46: Remote Controller

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Fig.2.10 Two wired controllers control multiple indoor units simultaneously. Note: Floor standing indoor unit only applicable to Fig.2.7 3 Remote Controller 3.1 Remote controller YAP1F Button name and function introduction...
  • Page 47: Remote Controller Yv1L1

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Button name Function ON/OFF Turn on or turn off the unit TURBO Set turbo function MODE Set operation mode Set up&down swing status I FEEL Set I FEEL function Switch temperature displaying type on the unit’s display TEMP Set health function and air function LIGHT...
  • Page 48: Panel Display

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Set quiet function Set health function and air function Set left&right swing status Set up&down swing status X-FAN Set X-FAN function TIMER ON Set timer on function TIMER OFF Set timer off function SAVE Set energy-saving function SLEEP...
  • Page 49 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) panel. (3) When the light of display panel is turned off, press the other buttons other than “Light” button, the light on display panel will be turned off after 5 seconds. 4.2.4 Temperature Setting Press “▼”or“▲”...
  • Page 50 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) the function setting status, the “ ” icon is off, it means the timer function has been canceled. Count down setting range: 00~24 hours, in which “00” refers to closedown of timer function. Each time press “▲”...
  • Page 51 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) cooling energy-saving function has been turned on. Turn on heating energy-saving: with the unit is started up, under heating mode, press “Function” button to switch to energy-saving function, press “▲”or “▼” button to adjust heating temperature limit, if the “...
  • Page 52: Introduction To Unit Functions

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) three times. (5) Settings of Child Lock Function Under power-on or power-off status, simultaneously press “▲” button and “▼” button for 5 seconds, it will turn on child lock function, the “88” LED will flicker and display “An” for three times; press “▲” button and “▼”...
  • Page 53 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Method 2: Step 1: Press and hold the “FUNCTION” button for five seconds in power-on or power-off status to enter the parameter query interface. Step 2: Press and hold the “FUNCTION” button for five seconds in "C00" status to enter the parameter setting interface.
  • Page 54 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) (2) Project number of multiple IDUs Project number query of IDUs in one-to-many mode: Press and hold the “FUNCTION” button for five seconds in power-on or power-off status to enter the parameter query interface "C00". Press “▽” to switch to “C01”.
  • Page 55 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) The user parameter query list is as follows: Table 2.1 User Parameter Query List Parameter Parameter Parameter View Method Code Name Range Display mode:  Timer area: displays the project number of the Parameter current IDU.
  • Page 56 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) environment environment temperature sensor of the master ODU. temperature query Operation method: In “C17” status, press the “MODE” button to enter the indoor relative humidity query interface. Press “▲” or “▼” to switch the IDU SN. Display mode: Indoor relative 20-90...
  • Page 57 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) and hold the “FUNCTION” button for another five seconds to enter the wired controller parameter setting interface. The temperature area displays “P00”. (2) Select a parameter code by pressing “ ” or “ ”. Press the “MODE” button to switch to parameter value settings.
  • Page 58 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 00: common timing Timer function settings 01: time-point timing Repeating 00: single timing validity for This setting is valid only when the timer function is set to time-point timing. time-point 01: repeated everyday timing Cooling setting temperature in...
  • Page 59 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Parameter Parameter Parameter Name View Method Code Range query of master number 00: no master Operation method: 1. In “C05” status, press the “MODE” button to enter the historical fault query interface. Press " "...
  • Page 60 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Parameter Parameter Parameter Name View Method Code Range Operation method: In “C15” status, press the “MODE” button to enter outlet temperature sensor query of IDU. Press " " or " " to switch the IDU SN.
  • Page 61 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Parameter Parameter Parameter Name View Method Code Range bit in the temperature area stops blinking, and the second and third bits in the temperature area display the parameter code. The timer area displays a corresponding parameter value. Press “▲”...
  • Page 62 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Parameter Parameter Parameter Name View Method Code Range In “nb” status, the timer area is not displayed. Press the “MODE” button to enter bar code query. The temperature area displays “nb” and the project number in the timer area blinks. Press “▲”...
  • Page 63 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) In parameter query status, signals of the remote controller are invalid. 5.1.6 Engineering Parameter Settings Engineering parameters can be set in power-on or power-off status. (1) Press and hold the “FUNCTION” button for five seconds. The temperature area displays “C00”. Continuously press the “MODE”...
  • Page 64 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Parameter Parameter Name Parameter Range Default Value Remark Code function of IDU Select "01" and then press and hold the “ENTER/CANCEL” button Factory setting 00: invalid to restore the factory settings for recovery for user user functions (factory setting 01: valid...
  • Page 65 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Parameter Parameter Name Parameter Range Default Value Remark Code factory departure. Press the “ENTER/CANCEL” button to confirm settings and return to the upper-level menu. Display mode: Temperature area: displays the target outlet temperature of fresh- air IDU.
  • Page 66 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Power-on High-pressure Protection Fault Interface Note: If the IDU connected with the current wired controller is a fresh-air IDU, “FAP” is displayed on the main interface of the wired controller. Only the outlet temperature can be set for the fresh- air IDU.
  • Page 67 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Method 2: Step 1: In power-on or power-off status, press and hold the “MODE” button and "SWING" simultaneously for five seconds to enter the parameter query interface. Step 2: In "C00" status, press and hold the “MODE” button and "SWING" simultaneously for five seconds to enter the parameter setting interface.
  • Page 68 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Engineering parameters can be queried in power-on or power-off status. (1) Press and hold the “MODE” and "SWING" button simultaneously for five seconds to enter the engineering parameter query interface. The temperature area displays “C00” and “VIEW” is on. (2) In "C00"...
  • Page 69 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Button name Function ON/OFF Turn on or turn off the unit Set fan speed ▲/▼ Set temperature and time MODE Set operation mode Set quiet function Set health function and air function Set left &...
  • Page 70 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.3.1 Master IDU Settings The master IDU can be set through the wired controller or remote controller. The methods for setting the master IDU through the remote controller are as follows: Step 1: Set an IDU to air-supply status and set the temperature to 30°...
  • Page 71 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Prompt time query for air filter cleaning Module 1 Module 2 Static pressure setting query of ODU Module 3 Module 4 Indoor unit quantity query in one-to-many control mode Temperature query for outdoor environment temperature sensor CAN2 bus line ID query Inlet-tube temperature query of IDU Outlet temperature query of IDU...
  • Page 72 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Setting Setting Content Setting Value Code 00: not cleared Historical fault clearing 01: cleared 01: temperature sensor of air return vent 02: temperature sensor of wired controller 03: temperature sensor of air return vent for cooling, dehumidifying, Indoor environment temperature and air supply;...
  • Page 73 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Setting Setting Content Setting Value Code  Heavy pollution: The first digit is "3". If the second digit is "0", it indicates that the accumulated operating time is 100 hours. The accumulated operating time is added by 100 hours when the second digit is increased by "1".
  • Page 74 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) LIGHT Set light function X-FAN Set X-FAN function SLEEP Set sleep function CLOCK Set clock of the system TOFF Set timer off function Set timer on function Set left&right swing status Set fan speed Set temperature and time (For details about the above figures, refer to the instructions 66174100016.)
  • Page 75: Installation

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) INSTALLATION...
  • Page 76: Engineering Installation Preparation And Notice

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 1 Engineering Installation Preparation and Notice 1.1 Installation notice Personnel and property safety are highly concerned during the entire installation process. Installation implementation must abide by relevant national safety regulations to ensure personnel and property safety.
  • Page 77: Installation Materials Selection

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Installation Problem Possible Consequence water pipe is incorrectly connected. The air channel is improperly The air channel will deform; vibration and noise occur during unit operating. fixed. The guide vane of air channel Uneven air quantity allocation reduces the overall performance of the air is not reasonably conditioner.
  • Page 78: Condensate Water Pipe

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) R410A Refrigerant System OD (mm/inch) Wall Thickness (mm) Model Φ6.35(1/4) ≥0.8 Φ9.52(3/8) ≥0.8 Φ12.70(1/2) ≥0.8 Φ15.9(5/8) ≥1.0 Φ19.05(3/4) ≥1.0 f. After the inner part of the copper pipe is cleaned and dried, the inlet and outlet must be sealed tightly by using pipe caps, plugs or adhesive tapes.
  • Page 79: Power Cable

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Communication cable selection for IDU and wired controller Total length of communication Cable Wire size Material Material type between IDU unit and Remarks /AWG) standard wired controller L(m/feet) 1. Total length of communication line can't exceed 250m (820- Light/Ordinary 1/5feet).
  • Page 80 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 81: Installation Of High Static Pressure Duct Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.2 Installation of High Static Pressure Duct Type unit 3.2.1 Outline and installation dimension Model: GMV-ND56PHS/A-T~ GMV-ND160PHS/A-T Below are dimensions of A, B, C, etc. for different models: Unit: mm/inch Model GMV-ND56PHS/A-T GMV-ND63PHS/A-T 1101...
  • Page 82 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 、 Model: GMV-ND224PH/A-T GMV-ND280PH/A-T Below are dimensions of A, B, C, etc. for different models: Unit: mm/inch Model 1353 1150 GMV-ND224PH/A-T (53-1/4) (24-7/8) (39) (45-1/4) (7-1/2) (12-7/8) 1563 1350 GMV-ND280PH/A-T (61-1/8) (27-3/4) (39) (53-1/8)
  • Page 83 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 84: Installation Of Low Static Pressure Duct Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) 220~240V/50Hz 1.0/AWG18 1.0/AWG18 GMV-ND100PHS/A-T 208~230V/60Hz 220~240V/50Hz GMV-ND112PHS/A-T 1.0/AWG18 1.0/AWG18 208~230V/60Hz 220~240V/50Hz GMV-ND125PHS/A-T 1.0/AWG18...
  • Page 85 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model:GMV-ND71PLS/A-T~GMV-ND140PLS/A-T...
  • Page 86 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 87: Installation Of 4-Way Cassette Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Minimum Sectional Minimum Sectional Air Switch apacity Area of Area of Power Model Power Cord Size Ground Wire Cord /AWG) /AWG) 220~240V/50Hz 1.0/AWG18 1.0/AWG18 GMV-ND50PLS/A-T 208~230V/60Hz 220~240V/50Hz 1.0/AWG18 1.0/AWG18 GMV-ND56PLS/A-T 208~230V/60Hz 220~240V/50Hz GMV-ND63PLS/A-T 1.0/AWG18...
  • Page 88 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 89: Installation Of Compact 4-Way Cassette Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) 220~240V/50Hz 1.0/AWG18 1.0/AWG18 GMV-ND63T/A-T 208~230V/60Hz 220~240V/50Hz GMV-ND71T/A-T 1.0/AWG18 1.0/AWG18 208~230V/60Hz 220~240V/50Hz GMV-ND80T/A-T 1.0/AWG18...
  • Page 90 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 91: Installation Of Compact 2-Way Cassette Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.5.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) 220~240V/50Hz GMV-ND22T/B-T 1.0/AWG18 1.0/AWG18 208~230V/60Hz...
  • Page 92 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 93: Installation Of Compact 1-Way Cassette Type Unit

    ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 94: Installation Of Floor Ceiling Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.7.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) 220~240V/50Hz GMV-ND22TD/A-T 1.0/AWG18 1.0/AWG18 208~230V/60Hz...
  • Page 95 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 96: Installation Of Fresh Air Processing Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.8.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) 220~240V/50Hz GMV-ND28ZD/A-T 1.0/AWG18 1.0/AWG18 208~230V/60Hz...
  • Page 97 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NDX224P/A-T、GMV-NDX280P/A-T The table below lists the detailed dimensions. Unit: mm Item Model GMV-NDX224P/A-T 1353 1150 GMV-NDX280P/A-T 1353 1150...
  • Page 98 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 99: Installation Of Slim Duct Type Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) GMV-NX450P/A(X4.0)-M 380-415V 3N ~50Hz 1.0/AWG18 1.0/AWG18 220~240V 1Ph 50Hz GMV-NDX224P/A-T 1.0/AWG18 1.0/AWG18 208~230V 1Ph 60Hz...
  • Page 100 ◆ Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 101: Installation Of Air Handler Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.11 Installation of Air Handler type Indoor Unit 3.10.1 Outline and installation dimension Unit: mm DIMENSION MODEL GMV-NR71A/A-D 1105 GMV-NR90A/A-D 1105 GMV-NR100A/A-D 1224 GMV-NR112A/A-D 1224 GMV-NR140A/A-D 1224 3.10.2 Installation notice When installing the air handler, take consideration to minimize the length of refrigerant tubing as much as possible.
  • Page 102 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.10.3 Selection of air switch and power cord Minimum Sectional Minimum Sectional Area of Circuit Area of Power Model Power Supply Breaker Ground Wire Cord Capacity (A) /AWG) /AWG) GMV-NR71A/A-D 208-230V~60Hz 1.0/AWG18 1.0/AWG18 GMV-NR90A/A-D...
  • Page 103 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) The table below lists the detailed dimensions. Unit: mm Item Model GMV-N22G/A3A-K, GMV-N28G/A3A-K, GMV-N22G/A2A-K GMV-N28G/A2A-K, GMV-N22G/A4A-K, GMV-N28G/A4A-K GMV-N22G/A8A-K, GMV-N28G/A8A-K, GMV-N22G/C9A-K GMV-N28G/C9A-K, GMV-N22G/E3A-K, GMV-N28G/E3A-K, GMV-N22G/A3A-D, GMV-N28G/A3A-D,GMV-N22G/A2A-D, GMV- N28G/A2A-D, GMV-N22G/A4A-D,GMV-N28G/A4A-D, GMV- N22G/A8A-D, GMV-N28G/A8A-D,GMV-N22G/C9A-D, GMV- N28G/C9A-D, GMV-N22G/E3A-D, GMV-N28G/E3A-D GMV-N36G/A3A-K, GMV-N45G/A3A-K, GMV-N50G/A3A-K GMV-N36G/A2A-K, GMV-N45G/A2A-K, GMV-N50G/A2A-K...
  • Page 104 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) ② If the tightening torque for the flare nut is too great, leakage would happen. 3.11.4 Selection of air switch and power cord Minimum Sectional Area of Minimum Sectional Area of Power Cord Air Switch apacity Model...
  • Page 105 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Minimum Sectional Area of Minimum Sectional Area of Power Cord Air Switch apacity Model Ground Wire Power Cord Size /AWG) /AWG) GMV-N22G/A3A-D, GMV- N22G/A2A-D GMV-N22G/A4A-D, GMV- 208~230V 1.0/AWG18 1.0/AWG18 N22G/A8A-D ~ 60Hz GMV-N22G/C9A-D, GMV- N22G/E3A-D GMV-N28G/A3A-D, GMV-...
  • Page 106: Console Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.12 Console Type Indoor Unit 3.12.1 Outline and installation dimension The table below lists the detailed dimensions. Unit: mm Item Model GMV-ND22C/A-T, GMV-ND28C/A-T GMV-ND36C/A-T, GMV-ND45C/A-T GMV-ND50C/A-T 3.12.2 Installation space (Unit:mm) 3.12.3 Installation notice Connect the ends of the connection pipe with two leading pipes, and then tighten the joint nuts tightly.
  • Page 107: Installation Of Super High Static Pressure Duct Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.13 Installation of Super High Static Pressure Duct Type Indoor Unit 3.13.1 Outline and installation dimension Model: GMV-ND22PHS/B-T~ GMV-ND160PHS/B-T Below are dimensions of A, B, C, etc. for different models: Unit: mm/inch Model GMV-ND22~50PHS/B-T 1040...
  • Page 108 ◆Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 109 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.13.4 Selection of air switch and power cord Minimum Sectional Minimum Sectional Air Switch Area of Area of Power Model Power Cord Size apacity Ground Wire Cord /AWG) /AWG) 220~240V/50Hz 1.0/AWG18 1.0/AWG18 GMV-ND22PHS/B-T 208~230V/60Hz...
  • Page 110: Installation Of Drain Pipe

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4 Installation of drain pipe 4.1 Precautions When Doing the Piping Work ◆ Keep piping as short as possible and slope it downwards at a gradient of at least 1/100 so that air may not remain trapped inside the pipe.
  • Page 111 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) ◆ If the air flow of indoor unit is high, this might cause negative pressure and result in return suction of outdoor air. Therefore, U-type water trap shall be designed on the drainage side of each indoor unit. ◆...
  • Page 112: Precautions When Doing Riser Piping Work

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) NO2: Connection of drain elbow NO3: Connection of horizontal pipe ◆ When unifying multiple drain pipes, install the pipes as shown below. Select converging drain pipes whose gauge is suitable for the operating capacity of the unit.(take the cassette type unit for example) 4.3 Precautions when doing riser piping work ◆...
  • Page 113: Testing Of Drain Piping

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) ◆ Secure a downward gradient of 1/100 or more for the drain pipe. To accomplish this, mount supporting brackets at an interval of 1 - 1.5 m.(take the cassette type unit for example) 4.4 Testing of Drain Piping ◆...
  • Page 114: Electrical Installation

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5 Electrical Installation ◆ The wiring must be in accordance with the local rules. ◆ Rated supply voltage and special circuit for air conditioner must be used. ◆ Do not pull the power cord forcefully. ◆...
  • Page 115 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) MAINTENANCE...
  • Page 116: Maintenance

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) MAINTENANCE 1 Troubleshooting 1.1 Malfunction list for the wired controller Display Display Display Content Content Content code code code Wrong number of indoor Malfunction of Malfunction of water unit for one-to-more indoor unit temperature sensor indoor unit...
  • Page 117: Floor Standing Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.1 Floor Standing Type GMV-ND100L/A-T, GMV-ND140L/A-T 3.2 High Static Pressure Duct Type GMV-ND56PHS/A-T、GMV-ND63PHS/A-T、GMV-ND71PHS/A-T、GMV-ND80PHS/A-T、 GMV-ND90PHS/A-T、GMV-ND100PHS/A-T、GMV-ND112PHS/A-T、GMV-ND125PHS/A-T、GMV- ND140PHS/A-T:...
  • Page 118 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-ND160PHS/A-T: GMV-ND224PH/A-T、GMV-ND280PH/A-T:...
  • Page 119: Low Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.3 Low Static Pressure Duct Type GMV-ND22PLS/A-T、GMV-ND25PLS/A-T、GMV-ND28PLS/A-T、GMV-ND32PLS/A-T GMV- ND36PLS/A-T、GMV-ND40PLS/A-T、GMV-ND45PLS/A-T、GMV-ND50PLS/A-T、GMV-ND56PLS/A- T、GMV-ND63PLS/A-T、GMV-ND71PLS/A-T、GMV-ND80PLS/A-T: GMV-ND90PLS/A-T 、GMV-ND100PLS/A-T、GMV-ND112PLS/A-T、GMV-ND125PLS/A-T、 GMV-ND140PLS/A-T:...
  • Page 120: 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.4 4-way Cassette Type GMV-ND28T/A-T、GMV-ND36T/A-T、GMV-ND45T/A-T、GMV-ND50T/A-T、GMV-ND56T/A- T、GMV-ND63T/A-T、GMV-ND71T/A-T、GMV-ND80T/A-T: GMV-ND90T/A-T、GMV-ND100T/A-T、GMV-ND112T/A-T、 GMV-ND125T/A-T、GMV- ND140T/A-T:...
  • Page 121: Compact 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-ND160T/A-T: 3.5 Compact 4-way Cassette Type GMV-ND22T/B-T、GMV-ND28T/B-T、GMV-ND36T/B-T、GMV-ND45T/B-T、GMV-ND50T/B-T、 GMV-ND56T/B-T...
  • Page 122: 2-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.6 2-way Cassette Type GMV-ND28TS/A-T、GMV-ND36TS/A-T、GMV-ND45TS/A-T、GMV-ND50TS/A-T、GMV- ND56TS/A-T、GMV-ND63TS/A-T、GMV-ND71TS/A-T: 3.7 1-way Cassette Type GMV-ND22TD/A-T、GMV-ND28TD/A-T、GMV-ND36TD/A-T、GMV-ND45TD/A-T、GMV- ND50TD/A-T...
  • Page 123: Floor Ceiling Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.8 Floor Ceiling Type GMV-ND28ZD/A-T、 GMV-ND36ZD/A-T、GMV-ND50ZD/A-T、GMV-ND63ZD/A-T、GMV- ND71ZD/A-T、GMV-ND90ZD/A-T、GMV-ND112ZD/A-T、GMV-ND125ZD/A-T、GMV-ND140ZD/A-T: 3.9 Fresh air Processing Unit GMV-NX140P/A(X1.2)-K:...
  • Page 124 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NX224P/A(X2.0)-M、GMV-NX280P/A(X2.5)-M、GMV-NX280P/A(X3.0)-M: GMV-NX450P/A(X4.0)-M:...
  • Page 125: Slim Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NDX224P/A-T、GMV-NDX280P/A-T 3.10 Slim Duct Type GMV-ND22PL/B-T、GMV-ND25PL/B-T、GMV-ND28PL/B-T、GMV-ND32PL/B-T、GMV- ND36PL/B-T、GMV-ND40PL/B-T、GMV-ND45PL/B-T、GMV-ND50PL/B-T、GMV-ND56PL/B-T、 GMV-ND63PL/B-T、GMV-ND72PL/B-T...
  • Page 126: Air Handler Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.11 Air Handler type Indoor Unit GMV-NR71A/A-D、GMV-NR90A/A-D、GMV-NR100A/A-D、GMV-NR112A/A-D、GMV-NR140A/A-...
  • Page 127: Console Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.12 Console Type Indoor Unit GMV-ND22C/A-T、GMV-ND28C/A-T、GMV-ND36C/A-T、GMV-ND45C/A-T、GMV-ND50C/A-T 3.13 Wall Mounted type Indoor Unit...
  • Page 128: Super High Static Pressure Duct Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 3.14 Super High Static Pressure Duct Type Indoor Unit GMV-ND22PHS/B-T、GMV-ND25PHS/B-T、GMV-ND28PHS/B-T、GMV-ND32PHS/B-T、GMV-ND36PHS/B-T、 GMV-ND40PHS/B-T、GMV-ND45PHS/B-T、GMV-ND50PHS/B-T、GMV-ND56PHS/B-T、GMV-ND63PHS/B-T、 GMV-ND71PHS/B-T、GMV-ND80PHS/B-T: GMV-ND90PHS/B-T、GMV-ND100PHS/B-T、GMV-ND112PHS/B-T、GMV-ND125PHS/B-T:...
  • Page 129 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-ND140PHS/B-T、GMV-ND160PHS/B-T:...
  • Page 130: Disassembly And Assembly Procedure Of Main Parts

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4 Disassembly And Assembly Procedure Of Main Parts 4.1 Floor Standing Type Removal and Assembly of electric box Remarks: Before removing the electric box, make sure to cut off the power firstly. Step Illustration Handling Instruction...
  • Page 131 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) and disassembly procedure is similar except the specifications of centrifugal fans and motors. Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the electric box 1.
  • Page 132: Low Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) ●Use a hexagon to 6. Remove the unscrew the fan and centrifugal fan. remove the centrifugal fan from the motor axle. ●Assemble units based 8. Install a new on the reverse order of motor.
  • Page 133: 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) ●Assemble units based on the 8. Install a new reverse order of this procedure and motor. power on the units for test. 4.4 4-way Cassette Type Motor and fan Step Diagram Operation Procedure Loosen the screws...
  • Page 134 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Motor and fan Step Diagram Operation Procedure 6. Replace the ●Replace the motor with a new one. motor with a new one. ●Use a screwdriver to screw the 7. Screw the motor.
  • Page 135 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Pump Step Diagram Operation Procedure ●Use a screwdriver to 1. Unscrew the water tray. unscrew the water tray. ●Replace the water tray. 2. Remove the water tray. 1. Unscrew the outlet pipe 3.
  • Page 136: Compact 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.5 Compact 4-way Cassette Type Motor and fan Step Diagram Operation Procedure 1. Unscrew ●Use a screwdriver to unscrew the water the water tray. tray. 2. Remove ●Remove the water tray. the water tray.
  • Page 137 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to unscrew 5. Unscrew the motor. the motor. 6. Replace ●Replace the motor with a new the motor with a new one.
  • Page 138 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Motor and fan Step Diagram Operation Procedure 8. Install and ●Install the centrifugal fan and screw the use a wrench to screw the centrifugal centrifugal fan. fan. 9. Install and ●Use a screwdriver to screw the screw the water tray water tray.
  • Page 139 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Pump Operation Step Diagram Procedure ●Replace the 2. Remove the water tray. water tray. 3. Remove the drainage duct 3. Remove the and use a drainage duct and screwdriver to unscrew the pump. unscrew the pump.
  • Page 140: 2-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Pump Operation Step Diagram Procedure ●Connect the drainage duct 5. Connect the and use a drainage duct and screwdriver to screw the new pump. screw the new pump. ●Use a 6. Install and screw the screwdriver to water tray.
  • Page 141 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Removal of Fan Motor Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew 2. the electric box cover. Remove the ●Remove from the master line connecting board the line connecting to the to the motor.
  • Page 142: 1-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.7 1-way Cassette Type Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to unscrew 1. Unscrew the water tray. the water tray. 2. Remove the ●Remove the water tray. water tray.
  • Page 143 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Motor and fan Step Diagram Operation Procedure 6. Remove the ●Remove the evaporator. evaporator. 7. Unscrew the ●Use a screwdriver to unscrew motor pressing the motor pressing board. board. 8. Remove the ●Remove the pressing board and pressing board and replace the...
  • Page 144 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Motor and fan Step Diagram Operation Procedure ●Use a screwdriver to screw the 11. Screw the outlet board. outlet board. 12. Put the ●Put the volute tongue back to volute tongue position.
  • Page 145: Floor Ceiling Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.8 Floor Ceiling Type Note: The following steps are specific for GMV-ND140ZD/A-T units. For other units, the assembly and disassembly procedure is similar except the numbers of centrifugal fans and motors. Motor and fan Precondition: The power supply has been disconnected.
  • Page 146 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew 7. Remove the front volute the front volute casing and casing. then remove the volute casing. ●Loosen the fasteners that 8.
  • Page 147: Fresh Air Processing Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.9 Fresh air Processing Unit GMV-NX140P/A (X1.2)-K Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the electric box 1. Remove the line cover.
  • Page 148 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NX224P/A(X2.0)-M、GMV-NX280P/A(X2.5)-M、GMV-NX280P/A(X3.0)-M Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the electric box cover. Remove the line ●Remove from the connecting to the master board the line motor.
  • Page 149 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NX450P/A(X4.0)-M Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to unscrew the electric box 1.Remove the line cover. ●Remove from the connecting to the motor.
  • Page 150 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NDX224P/A-T、GMV-NDX280P/A-T Motor and fan Precondition: The power supply has been disconnected. Step Diagram Operation Procedure ●Use a screwdriver to 1. Remove the cover unscrew the cover plate plate component. component. ●Use a screwdriver to unscrew the electric box 2.
  • Page 151: Slim Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.10 Slim Duct Type Note: The following steps are specific for GMV-ND22PL/B-T units. For other units, the assembly and disassembly procedure is similar except the numbers of louvers and motors. Motor and fan Precondition: The power supply has been disconnected.
  • Page 152: Console Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.11 Console Type Indoor Unit Note: The following steps are specific for GMV-ND22C/A-T units. For other units, the assembly and disassembly procedure is similar except the numbers of louvers and motors. Removal of Fan Motor Remark: before removing, making sure power is disconnected.
  • Page 153: Wall Mounted Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.12 Wall Mounted type Indoor Unit Note: The following steps are specific for GMV-N22G/A3A-K units. For other units, the assembly and disassembly procedure is similar except the numbers of louvers and motors. Removal of Fan Motor Remark: before removing, making sure power is disconnected.
  • Page 154 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Removal of Fan Motor Remark: before removing, making sure power is disconnected. Step Diagram Operation Procedure ●Unscrew the screws fixing the 7. Remove the electrical box with a screwdriver. electrical box ●Remove the electrical box.
  • Page 155: Super High Static Pressure Duct Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 4.13 Super High Static Pressure Duct Type Indoor Unit Note: The following steps are specific for GMV-ND22PHS/B-T units. For other units, the assembly and disassembly procedure is similar except the specifications of centrifugal fans and motors. Motor and fan Precondition: The power supply has been disconnected.
  • Page 156: Exploded Views And Part List

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5 Exploded Views And Part List 5.1 Floor Standing Type Exploded View of GMV-ND100L/A-T, GMV-ND140L/A-T Model GMV-ND100L/A-T GMV-ND140L/A-T Product Code CM300N0060 CM300N0070 Part Name Part Code Part Code Air Outlet Panel Assy...
  • Page 157: High Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-ND100L/A-T GMV-ND140L/A-T Product Code CM300N0060 CM300N0070 Part Name Part Code Part Code Air Guard Assy 01354100012 01354100012 Cover of Pass Wire slot 01744109 01744109 Pass Wire slot 02164010 02164010 Protective Covering...
  • Page 158 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND56PHS/A-T CM800N3690 Name of part GMV-ND63PHS/A-T CM800N3700 GMV-ND71PHS/A-T CM800N3540 GMV-ND80PHS/A-T CM800N3710 Part code Quantity Filter Sub-Assy '11125303 Guide groove of the filter '02285301 screen Evaporator Assy '01024100090 Electric Expand Valve Fitting...
  • Page 159 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND90PHS/A-T、GMV-ND100PHS/A-T、GMV-ND112PHS/A-T、GMV-ND125PHS/A-T、 GMV-ND140PHS/A-T: For the following unit Unit Product Code GMV-ND90PHS/A-T CM800N3550 GMV-ND100PHS/A-T CM800N3650 Name of part GMV-ND112PHS/A-T CM800N3660 GMV-ND125PHS/A-T CM800N3670 GMV-ND140PHS/A-T CM800N3680 Part code Quantity Filter Sub-Assy '111253031 Side Plate of Air intake '01375301 Evaporator Assy...
  • Page 160 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND90PHS/A-T CM800N3550 GMV-ND100PHS/A-T CM800N3650 Name of part GMV-ND112PHS/A-T CM800N3660 GMV-ND125PHS/A-T CM800N3670 GMV-ND140PHS/A-T CM800N3680 Part code Quantity Right Side Plate Sub-Assy '01315200100 Electric Box Assy '01394100255 Main Board '30226000027...
  • Page 161 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND160PHS/A-T: Model GMV-ND160PHS/A-T Product Code CM810N0250 Qty. Part Name Part Code Front Side Plate Sub-Assy '01315200091 Blower Mounting Plate Sub-Assy '01325200057 Support plate sub-assy (motor) '0189520001401 Propeller Housing(Lower) '26905200011 Motor Support '01805200228...
  • Page 162 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-ND160PHS/A-T Product Code CM810N0250 Qty. Part Name Part Code Reactor '43138000047 Current Divider '07222706 Strainer '0741410000601 Electronic Expansion Valve '07334468 Electric Expand Valve Fitting '4304413215 Water Level Switch '4501270301 Filter Sub-Assy '111253036 Evaporator Assy '01024100157...
  • Page 163 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-ND224PH/A-T: Exploded View of GMV-ND280PH/A-T:...
  • Page 164 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND224PH/A- GMV-ND280PH/A- CM800N3721 CM800N3731 Part code Quantity Part code Quantity Front Side Plate Sub-Assy '01314627 `01314315 Centrifugal fan assy...
  • Page 165: Low Static Pressure Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.3 Low Static Pressure Duct Type Exploded View of GMV-ND22PLS/A-T、GMV-ND25PLS/A-T、GMV-ND28PLS/A-T、GMV-ND32PLS/A- T GMV-ND36PLS/A-T: For the following unit For the following unit Unit Product Code Unit Product Code GMV- GMV- CM800N3370 CM800N3390 ND22PLS/A-T ND32PLS/A-T Name of part GMV-...
  • Page 166 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code GMV- GMV- CM800N3370 CM800N3390 ND22PLS/A-T ND32PLS/A-T Name of part GMV- GMV- CM800N3380 CM800N3500 ND25PLS/A-T ND36PLS/A-T GMV- CM800N3490 ND28PLS/A-T Part code Quantity...
  • Page 167 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND40PLS/A-T、GMV-ND45PLS/A-T、GMV-ND50PLS/A-T: For the following unit Unit Product Code GMV-ND40PLS/A-T CM800N3400 Name of part GMV-ND45PLS/A-T CM800N3410 GMV-ND50PLS/A-T CM800N3420 Part code Quantity Filter Sub-Assy '11725210 Rotary Axis Sub-Assy '73018020 Joint Slack '73018731 Fan Motor '15704100001...
  • Page 168 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND40PLS/A-T CM800N3400 Name of part GMV-ND45PLS/A-T CM800N3410 GMV-ND50PLS/A-T CM800N3420 Part code Quantity Electric Box Cover '01424100035 Sealplate sub-assy (drainage) '01495315 Sealplate sub-assy (outlet) '01495316 Left Side Plate Assy '01315200087 Main Board...
  • Page 169 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND56PLS/A-T、GMV-ND63PLS/A-T: For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV- GMV- CM800N3510 CM800N3430 ND56PLS/A-T ND63PLS/A-T Part code Quantity Part code Quantity Filter Sub-Assy '11725208...
  • Page 170 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV- GMV- CM800N3510 CM800N3430 ND56PLS/A-T ND63PLS/A-T Part code Quantity Part code Quantity Terminal Board '4201800002601 '4201800002601 Electric Box Cover...
  • Page 171 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND71PLS/A-T、GMV-ND80PLS/A-T: For the following unit Unit Product Code Name of part GMV-ND71PLS/A-T CM800N3520 GMV-ND80PLS/A-T CM800N3440 Part code Quantity Filter Sub-Assy '11725207 Air Intake Side Board Sub- '02225265 assy Rear volute casing '26905209 Fan Motor...
  • Page 172 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code Name of part GMV-ND71PLS/A-T CM800N3520 GMV-ND80PLS/A-T CM800N3440 Part code Quantity Humidity Sensor Electric Box Assy '01394100205 Main Board '30226000029 Terminal Board '4201800002601 Terminal Board '42011106 Electric Box Cover '01425262...
  • Page 173 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND90PLS/A-T 、GMV-ND100PLS/A-T、GMV-ND112PLS/A-T、GMV- ND125PLS/A-T、GMV-ND140PLS/A-T: For the following unit For the following unit Unit Product Code Unit Product Code GMV- GMV- CM800N3450 CM800N3480 ND90PLS/A-T ND125PLS/A-T Name of part GMV- GMV- CM800N3460 CM800N3470 ND100PLS/A-T...
  • Page 174 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code GMV- GMV- CM800N3450 CM800N3480 ND90PLS/A-T ND125PLS/A-T Name of part GMV- GMV- CM800N3460 CM800N3470 ND100PLS/A-T ND140PLS/A-T GMV- CM800N3530 ND112PLS/A-T Part code Quantity...
  • Page 175: 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.4 4-way Cassette Type Exploded View of GMV-ND28T/A-T、GMV-ND36T/A-T、 GMV-ND45T/A-T、GMV-ND50T/A-T、GMV- ND56T/A-T、GMV-ND63T/A-T、GMV-ND71T/A-T、GMV-ND80T/A-T、 : For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28T/A-T CM500N0380 GMV-ND36T/A-T CM500N0390 Part code Quantity...
  • Page 176 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28T/A-T CM500N0380 GMV-ND36T/A-T CM500N0390 Part code Quantity Part code Quantity Rear Side Plate Assy '01302719 '01302719 Brushless DC Motor...
  • Page 177 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code GMV-ND45T/A-T CM500N0400 GMV-ND56T/A-T CM500N0420 Name of part GMV-ND50T/A-T CM500N0410 GMV-ND63T/A-T CM500N0430 GMV-ND71T/A-T CM500N0440 GMV-ND80T/A-T CM500N0450 Part code Quantity Part code Quantity...
  • Page 178 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Above data is subject to change without notice,pls refer the SP in global service website. Exploded View of GMV-ND90T/A-T、GMV-ND100T/A-T、GMV-ND112T/A-T、 GMV-ND125T/A-T、GMV- ND140T/A-T: For the following unit Unit Product Code GMV-ND90T/A-T CM500N0460 GMV-ND100T/A-T CM500N0470 Name of part GMV-ND112T/A-T...
  • Page 179 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND90T/A-T CM500N0460 GMV-ND100T/A-T CM500N0470 Name of part GMV-ND112T/A-T CM500N0480 GMV-ND125T/A-T CM500N0480 GMV-ND140T/A-T CM800N0550 Part code Quantity Front Side Plate assy '01302713 Base Plate Assy '01222701 Rear Side Plate Assy '01302709...
  • Page 180 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND160T/A-T: Note: Details of this model are not issued yet. This list is made according to domestic sales details and cannot be used to place order for accessories. It will be updated once the following details are issued. For the following unit Unit Product Code...
  • Page 181: Compact 4-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code Name of part GMV-ND160T/A-T CM500N0660 Part code Quantity Centrifugal Fan '10429401 Humidity Sensor Filter Sub-Assy '07210029 Electronic Expansion '07334468 Valve Strainer '0741410000601 Drain Hose Sub-Assy '05232702 Water Tray Assy '01289400002...
  • Page 182 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND22T/B-T、GMV-ND28T/B-T、GMV-ND36T/B-T、GMV-ND45T/B-T、GMV-ND50T/B- T、GMV-ND56T/B-T GMV-ND22T/B-T GMV-ND28T/B-T GMV-ND36T/B-T Model GMV-ND45T/B-T GMV-ND50T/B-T GMV-ND56T/B-T CM500N0610 CM500N0620 CM500N0630 Product Code CM500N0640 CM500N0600 CM500N0650 Part Name Part Code Base Plate Assy 02229400007 Evaporator Assy 01024100137 Water Tray Assy 01289400004 Liquid Level Switch...
  • Page 183: 2-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-ND22T/B-T GMV-ND28T/B-T GMV-ND36T/B-T Model GMV-ND45T/B-T GMV-ND50T/B-T GMV-ND56T/B-T CM500N0610 CM500N0620 CM500N0630 Product Code CM500N0640 CM500N0600 CM500N0650 Part Name Part Code Remote Controller 30510589 Drain Hose Sub-Assy 05232050 Strainer 0741410000601 Electronic Expansion Valve 07334463 Electric Expand Valve Fitting 4304413215...
  • Page 184 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-ND28TS/A-T、 GMV-ND56TS/A-T、 GMV-ND36TS/A-T、 Model GMV-ND63TS/A-T、 GMV-ND45TS/A-T、 GMV-ND71TS/A-T GMV-ND50TS/A-T CM500N0680 CM500N0720 CM500N0690 Product Code CM500N0730 CM500N0700 CM500N0740 CM500N0710 Part Name Part Code Part Code Remote Controller 30510589 30510589 Drain Hose Sub-Assy 05232050 05232050 Sensor Sub-assy 39008000013G...
  • Page 185: 1-Way Cassette Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.7 1-way Cassette Type Exploded View of GMV-ND22TD/A-T、GMV-ND28TD/A-T、GMV-ND36TD/A-T、GMV-ND45TD/A-T、GMV- ND50TD/A-T: For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28TD/A- GMV-ND36TD/A- CM502N0100 CM502N0110 Part code Quantity Part code Quantity...
  • Page 186 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND28TD/A- GMV-ND36TD/A- CM502N0100 CM502N0110 Part code Quantity Part code Quantity Water Pump Assy '15404100005 '15404100005 Pump Drainpipe '26905288...
  • Page 187 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit For the following unit Unit Product Code Unit Product Code Name of part GMV-ND45TD/A- GMV-ND50TD/A- CM502N0120 CM502N0130 Part code Quantity Part code Quantity Remote Controller '30510589 '30510589 Drain Hose Sub-Assy '05232050 '05232050...
  • Page 188: Floor Ceiling Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.8 Floor Ceiling Type Exploded View of GMV-ND28ZD/A-T、 GMV-ND36ZD/A-T、GMV-ND50ZD/A-T、GMV-ND56ZD/A-T : For the following unit Unit Product Code GMV-ND28ZD/A-T CM600N0350 Name of part GMV-ND36ZD/A-T CM600N0360 GMV-ND50ZD/A-T CM600N0320 Part code Quantity Sensor Sub-assy '39008000101G Connection Board '02229406...
  • Page 189 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Front Connection Board '01349414P Air Louver '10619404 Rotating Shaft '26909430 Guide Louver Supporter Sub- '0180941601 assy Fixed Mount '26909426R Display Board '30294000009 Rear Side Plate Assy '01319400008 '01024100126(28) Evaporator Assy '01024100096(36、50) Rotating Shaft '26909413 Connecting Rod...
  • Page 190 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND63ZD/A-T、GMV-ND71ZD/A-T、GMV-ND90ZD/A-T: For the following unit Unit Product Code GMV-ND63ZD/A-T CM600N0410 Name of part GMV-ND71ZD/A-T CM600N0370 GMV-ND90ZD/A-T CM600N0330 Part code Quantity Remote Controller '30510589 Sensor Sub-assy '39008000100G Water Tray Assy '01289405 Swing Lever '10582008...
  • Page 191 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND63ZD/A-T CM600N0410 Name of part GMV-ND71ZD/A-T CM600N0370 GMV-ND90ZD/A-T CM600N0330 Part code Quantity Releasing Flume Water Releasing Flume '26909441 connected board (evaporator) '01344108 Strainer '0741410000601 Electronic Expansion Valve ' 07334466 Electric expand valve fitting...
  • Page 192 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND63ZD/A-T CM600N0410 Name of part GMV-ND71ZD/A-T CM600N0370 GMV-ND90ZD/A-T CM600N0330 Part code Quantity Centrifugal fan '1041410101 Front volute casing '26905208 Rear Connection board '01349418 Rotary Axis Sub-Assy '73018052 Joint Slack '73018731...
  • Page 193 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND112ZD/A-T CM600N0380 Name of part GMV-ND125ZD/A-T CM600N0390 GMV-ND140ZD/A-T CM600N0340 Part code Quantity Remote Controller '30510589 Sensor Sub-assy '39008000100G Water Tray Assy '01289401 Air Louver '26909418 Connection Board '02229406...
  • Page 194 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND112ZD/A-T CM600N0380 Name of part GMV-ND125ZD/A-T CM600N0390 GMV-ND140ZD/A-T CM600N0340 Part code Quantity Left Cover Plate '26909416 Main Board '30226000027 Terminal Board '42011106 Terminal Board '4201800002601 Inductance '43128000014...
  • Page 195: Fresh Air Processing Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.9 Fresh air Processing Unit Exploded View of GMV-NX140P/A(X1.2)-K: Model GMV-NX140P/A(X1.2)-K Product Code CM800N3610 Qty. Part Name Part Code Electric Box Cover 01424100071 Terminal Board 42011106 Electric Box Assy 01394100199 Left Side Plate Assy 01314100058 Seal Of Left Side Plate Sub-Assy 01495212...
  • Page 196 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Fan Motor Mounting Plate Sub-Assy 01325293 Blower 15018603 Fan Motor 1570520901 Blower 15018604 Air intake side-board Sub-assy 01375221 Fan Motor 1570521001 Filter Sub-Assy 11725205 Main Board 30226000052 Capacitor CBB61 33010056 Capacitor CBB61 33010064 Terminal Board 4201800002601...
  • Page 197 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-NX224P/A(X2.0)-M Product Code CM800N3620 Qty. Part Name Part Code Filter 07415210 Strainer 0741410000601 Electronic Expansion Valve 07334390 Evaporator Assy 1024100064 Filter Sub-Assy 11129070 Air Guard 01354111 Cover Plate Sub-Assy of Evaporator 01094109 Left Side Plate Assy 01314208...
  • Page 198 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-NX280P/A(X2.5)-M GMV-NX280P/A(X3.0)-M Product Code CM800N3630 CM800N3630 Qty. Part Name Part Code Part Code Electric Box Cover 014191411 014191411 AC Contactor 44010232 44010232 Terminal Board 420100071 420100071 Terminal Board 4201800002601 4201800002601 Main Board 30226000052 30226000052...
  • Page 199 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-NX450P/A(X4.0)-M: Model GMV-NX450P/A(X4.0)-M Product Code CM800N3740 Qty. Part Name Part Code Electric Box Cover 01425304P Electric Box Assy 01394100243 Terminal Board 42011043 AC Contactor 44010232 Terminal Board 4201800002601 Main Board 30226000052 Air Outlet Panel sub-assy...
  • Page 200 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-NX450P/A(X4.0)-M Product Code CM800N3740 Qty. Part Name Part Code Gas Tube Filter 072190511 Side panel sub-assy 01545208 Side panel sub-assy 01545210 Fan Motor 1501861102 Belt Wheel 10548149 Taper Sleeve 10548213 Taper Sleeve 10548218 Belt Wheel...
  • Page 201 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-NDX224P/A-T GMV-NDX280P/A-T Product Code CM810N0260 CM810N0270 Qty. Part Name Part Code Part Code Display Board 30296000040 30296000040 Sensor Sub-Assy 39004165G 39004165G Left Side Plate Assy 2 01315367 01315367 Hook 02112466 02112466 Left Side Plate Sub-Assy 1 01315376...
  • Page 202: Slim Duct Type

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.10 Slim Duct Type Exploded View of GMV-ND22PL/B-T、GMV-ND25PL/B-T、GMV-ND28PL/B-T、GMV-ND32PL/B-T GMV- ND36PL/B-T: For the following unit Unit Product Code GMV-ND22PL/B-T CM800N3560 GMV-ND25PL/B-T CM810N0010 Name of part GMV-ND28PL/B-T CM810N0020 GMV-ND32PL/B-T CM800N3570 GMV-ND36PL/B-T CM810N0030 Part code Quantity Propeller Housing(Upper) ` 26905200018...
  • Page 203 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Terminal Board ' 4201800002601 Main Board ` 30226000029 Electric Box Cover ` 01425200023 Electric Box Assy ` 01394100160 Closing Plate Sub-Assy ` 01494100010 Left Side Plate Assy ` 01314100076 Air Outlet Frame Assy ` 01374100057 Hook ` 02112446...
  • Page 204 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND40PL/B-T CM800N3580 GMV-ND45PL/B-T CM810N0040 Name of part GMV-ND50PL/B-T CM810N0050 GMV-ND56PL/B-T CM800N3590 GMV-ND63PL/B-T CM810N0060 Part code Quantity Centrifugal fan assy ` 15404100032 Centrifugal Fan ` 10425200003 Fan Bearing ` 76512210 Joint Slack...
  • Page 205 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND72PL/B-T: For the following unit Unit Product Code Name of part GMV-ND72PL/B-T CM800N3600 Part code Quantity Centrifugal fan assy ` 15404100032 Bearing Holder Sub-assy ` 26151139 Centrifugal Fan ` 10425200003 Fan Bearing ` 76512210...
  • Page 206: Air Handler Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Electric Box Cover ` 01425200023 Closing Plate Sub-Assy ` 01494100010 Right Side Plate Assy ` 01315200053 Electronic Expansion Valve ` 07334466 Air Outlet Frame Assy ` 01374100059 Top Cover Board Assy ` 0126520009201 Hook ` 02112446...
  • Page 207 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NR140A/A-D Model GMV-NX224P/A(X2.0)-M Product Code CM800N3620 Qty. Part Name Part Code insulating board '75142201 Lower cover plate 1 01264100065 Top Cover Board Sub-assy '01262200024 Plastic Cover '26902209 Lower cover plate sub-assy 2 '01262200026 Evaporator Assy '01024100159...
  • Page 208 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Filter Sub-Assy ` 1172220202 Motor for Centrifugal Fan ` 1570220101 Fan Motor ` 1570221401 Right Side Plate Sub-Assy ` 01312200007 Rear Side Plate Sub-Assy ` 01312200009 Blower Mounting Plate ` 01322200008 Electric cabinet board ` 01394100523 Capacitor CBB65...
  • Page 209 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-NR100A/A-D、 Model GMV-NX224P/A(X2.0)-M Product Code CM800N3620 Qty. Part Name Part Code insulating board ` 75142201 Lower cover plate 1 ` 01264100069 Top Cover Board Sub-assy ` 01262200019 Plastic Cover ` 26902209 Lower cover plate sub-assy 2 ` 01262200017 Evaporator Assy...
  • Page 210: Console Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Model GMV-NX224P/A(X2.0)-M Product Code CM800N3620 Qty. Part Name Part Code Filter Sub-Assy ` 1172220201 Motor for Centrifugal Fan ` 1570220201 Fan Motor ` 15702245 Right Side Plate Sub-Assy ` 01312200017 Rear Side Plate Sub-Assy ` 01312200019 Blower Mounting Plate ` 01322200006...
  • Page 211 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-ND22C/A-T CM400N0140 GMV-ND28C/A-T CM400N0070 Name of part GMV-ND36C/A-T CM400N0080 GMV-ND45C/A-T CM400N0150 GMV-ND50C/A-T CM400N0090 Part code Quantity Front Panel Assy ` 20012756 Filter Sub-Assy ` 11122139 Front Case Assy ` 20012601 Air Louver(lower)
  • Page 212: Wall Mounted Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Crank ` 73012005 Stepping Motor ` 1521210101 Display Board ` 30568131 Pinboard ` 30278000001 Terminal Board ` 42010268 Electric Board ` 20112116 Main Board ` 30226000080 Magnetic Ring ` 49010104 Shield Cover of Electric Box ` 01592169 Sub-assy Remote Controller...
  • Page 213 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Front Case Sub-assy '2001213931 Evaporator Assy 01024100097 Strainer '07414100006 ...4 Strainer '07213050 ...4 Electronic Expansion Valve '07334463 ...4 Electric Expand Valve Fitting '4304413217 Axile Bush '10542036 Rear Grill '01472013 Motor Press Plate '26904100117 Fan Motor '1501208905...
  • Page 214 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) GMV-N36G/A3A-K、GMV-N45G/A3A-K、GMV-N50G/A3A-K For the following unit Unit Product Code GMV-N36G/A3A-K CM100N1360 Name of part GMV-N45G/A3A-K CM100N1370 GMV-N50G/A3A-K CM100N1330 Part code Quantity Receiver Window 22432173 Guide Louver 10512115 Front Panel Assy 20012260 Filter Sub-Assy 1112000000 Front Case Sub-assy 20022172...
  • Page 215 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Electric Box Assy 1394000000 Main Board 30230000000 Terminal Board 42010268 Electric Box 2011000000 Connecting pipe clamp 26112164 SteppingMotor 15012086 Crank 10582070 Wall Mounting Frame 1252218 Rear Case Sub-Assy 2220000000 Air Louver 1 10512708 Air Louver 2 10512709...
  • Page 216 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) For the following unit Unit Product Code GMV-N56G/A3A-K CM100N1380 Name of part GMV-N63G/A3A-K CM100N1390 GMV-N71G/A3A-K CM100N1320 Part code Quantity Receiver Window '22432230 Guide Louver '10512157 Front Panel B1 '20012122S Filter Sub-Assy 1112220403 Front Case Sub-assy '2001213931...
  • Page 217: Super High Static Pressure Duct Type Indoor Unit

    MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 5.14 Super High Static Pressure Duct Type Indoor Unit Exploded View o f GMV-ND22PHS/B-T、GMV-ND25PHS/B-T、GMV-ND28PHS/B-T、GMV-ND32PHS/B-T、GMV- ND36PHS/B-T: For the following unit Unit Product Code GMV-ND22PHS/B-T CM810N0300 GMV-ND25PHS/B-T CM810N0310 Name of part GMV-ND28PHS/B-T CM810N0320 GMV-ND32PHS/B-T CM810N0330 GMV-ND36PHS/B-T...
  • Page 218 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Hook '02112466 Centrifugal Fan Assy '15404100074 Propeller Housing(Upper) '26905200078 Return Air Frame Sub-Assy '017026000004 Centrifugal Fan '10455200003 Supporter(Fan motor) '0180520027201 Brushless DC Motor '1570520000501 Propeller Housing(Lower) '26905200079 Filter Sub-Assy 111001000055 Foam Sub-assy '12505200038 Cover Of Air-In '01265200182...
  • Page 219 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View o f GMV-ND40PHS/B-T、GMV-ND45PHS/B-T、GMV-ND50PHS/B-T: For the following unit Unit Product Code GMV-ND40PHS/B-T CM810N0350 Name of part GMV-ND45PHS/B-T CM810N0360 GMV-ND50PHS/B-T CM810N0370 Part code Quantity Display Board '30296000040 Drain Hose Sub-Assy '05232050 Temperature Sensor '390000454 Temperature Sensor...
  • Page 220 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Centrifugal Fan '10455200003 Supporter(Fan motor) '0180520027201 Brushless DC Motor '1570520000501 Propeller Housing(Lower) '26905200079 Filter Sub-Assy 111001000055 Foam Sub-assy '12505200038 Cover Of Air-In '01265200182 Bottom Cover Plate '01265200181 Left Side Plate Assy '01315200147 Inductance '43128000014...
  • Page 221 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND56PHS/B-T、GMV-ND63PHS/B-T、GMV-ND71PHS/B-T、GMV-ND80PHS/B-T: For the following unit Unit Product Code GMV-ND56PHS/B-T CM810N0380 Name of part GMV-ND63PHS/B-T CM810N0390 GMV-ND71PHS/B-T CM810N0400 GMV-ND80PHS/B-T CM810N0410 Part code Quantity '017026000002 Centrifugal Fan Assy '111001000045 Filter Sub-Assy '26905200078 Propeller Housing(Upper) '10455200003...
  • Page 222 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) '01495200079 Seal plate Assy '45020216 Water Level Switch '43138000058 Water Pump '01315200147 Left Side Plate Assy '100002000985 Electric Box Assy '43128000014 Inductance '4201115402 Terminal Board '30226000089 Main Board '4201800002601 Terminal Board '01375200026 Air Outlet Frame Assy '01024100173...
  • Page 223 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND90PHS/B-T、GMV-ND100PHS/B-T、GMV-ND112PHS/B-T、GMV-ND125PHS/B-T: 27 26 25 严禁在 潮湿场 所使 用 18 19 20 21 22 15 16 17 9 10 11 13 14 For the following unit Unit Product Code GMV-ND90PHS/B-T CM810N0420 Name of part...
  • Page 224 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Choke Plug Of Drain Pipe '76815214 Cover Plate(Air Return) '01265200123 Bottom Cover Plate '01265200125 Left Side Plate Assy '01315200147 Hook '02112466 Water Level Switch '45020216 Water Pump '43138000058 Seal Plate 01495200078 Reactor '43138000047 Terminal board...
  • Page 225 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) Exploded View of GMV-ND140PHS/B-T、GMV-ND160PHS/B-T: 27 26 25 严 禁 在 潮 湿 场 所 使 用 13 14 15 16 17 18 19 21 22 23 9 10 11 For the following unit Unit Product Code Name of part...
  • Page 226 MULTI VRF-Ⅱ INDOOR UNIT SERVICE MANUAL EUROPEAN/LATIN AMETICA (R410A) 30221000033 Main Board '43138000047 Reactor 30226000092 Main Board 4201115402 Terminal board 4201800002601 Terminal Board '100002001512 Electric Box Assy '45020216 Water Level Switch '43138000058 Water Pump '01495200078 Seal Plate '3900005910 Temperature Sensor '390000592 Temperature Sensor '390000454...
  • Page 227 JF00302966...

This manual is also suitable for:

Gmv-nd140l/a-t gmv-nd56phs/a-tGmv-nd63phs/a-tGmv-nd71phs/a-tGmv-nd80phs/a-tGmv-nd90phs/a-tGmv-nd100phs/a-t ... Show all

Table of Contents