Programming the Logic Analyzer
To copy commands to \system\program
Example
Programming the logic analyzer over an NFS mount with a file
Suppose machine 1 is configured as a state analyzer. To clear the format and
trigger set-ups of machine 1, first create the following command file.
File clear.txt:
:SELECT 1
:MACHINE1:SFORMAT:REMOVE ALL
:MACHINE1:STRIGGER:CLEAR ALL
The first command selects the analyzer to receive programming commands.
The second command clears the format set-up. The third command clears
the trigger set-up.
Now copy the file to the logic analyzer. At the MS-DOS prompt, enter:
copy clear.txt L:\system\program
If your computer runs the UNIX operating system, you might use the cp
command. In an MS Windows environment, you can use File Manager.
See Also
The Programmer's Guide for your logic analyzer for a detailed description of
the commands. The Programmer's Guide can be ordered from your Agilent
Technologies Sales Office.