GE AF-650 GP Programming Manual page 155

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

[93]
Mech. brake control
[94]
Safe stop active
[100]
Comparator 0
[101]
Comparator 1
[102]
Comparator 2
[103]
Comparator 3
3
[104]
Comparator 4
[105]
Comparator 5
[110]
Logic rule 0
[111]
Logic rule 1
[112]
Logic rule 2
[113]
Logic rule 3
[114]
Logic rule 4
[115]
Logic rule 5
[120]
Logic Controller Time-out 0
[121]
Logic Controller Time-out 1
[122]
Logic Controller Time-out 2
[123]
Logic Controller Time-out 3
[124]
Logic Controller Time-out 4
[125]
Logic Controller Time-out 5
[126]
Logic Controller Time-out 6
[127]
Logic Controller Time-out 7
[130]
Digital input DI18
[131]
Digital input DI19
[132]
Digital input DI27
[133]
Digital input DI29
[134]
Digital input DI32
[135]
Digital input DI33
[150]
LC digital output A
[151]
Logic Controller digital output B
[152]
Logic Controller digital output C
[153]
Logic Controller digital output D
[154]
Logic Controller digital output E
[155]
Logic Controller digital output F
[160]
Relay 1
[161]
Relay 2
[180]
Local referecnce active
154
Mech. brake control [93] The mechanical brake is active.
Comparator 0 [100] The result of comparator 0.
Comparator 1 [101] The result of comparator 1.
Comparator 2 [102] The result of comparator 2.
Comparator 3 [103] The result of comparator 3.
Comparator 4 [104] The result of comparator 4.
Comparator 5 [105] The result of comparator 5.
Logic rule 0 [110] The result of Logic rule 0.
Logic rule 1 [111] The result of Logic rule 1.
Logic rule 2 [112] The result of Logic rule 2.
Logic rule 3 [113] The result of Logic rule 3.
Logic rule 4 [114] The result of Logic rule 4.
Logic rule 5 [115] The result of Logic rule 5.
SL Time-out 0 [120] The result of LC timer 0.
SL Time-out 1 [121] The result of LC timer 1.
SL Time-out 2 [122] The result of LC timer 2.
SL Time-out 3 [123] The result of LC timer 3.
SL Time-out 4 [124] The result of LC timer 4.
SL Time-out 5 [125] The result of LC timer 5.
SL Time-out 6 [126] The result of LC timer 6.
SL Time-out 7 [127] The result of LC timer 7.
Digital input DI18 [130] Digital input 18. High = True.
Digital input DI19 [131] Digital input 19. High = True.
Digital input DI27 [132] Digital input 27. High = True.
Digital input DI29 [133] Digital input 29. High = True.
Digital input DI32 [134] Digital input 32. High = True.
Digital input DI33 [135] Digital input 33. High = True.
SL digital output B [151] Use the result of the LC output B.
SL digital output C [152] Use the result of the LC output C.
SL digital output D [153] Use the result of the LC output D.
SL digital output E [154] Use the result of the LC output E.
SL digital output F [155] Use the result of the LC output F.
Relay 1 [160] Relay 1 is active
Relay 2 [161] Relay 2 is active
Local ref. active [180] High when par. F-02 Operation Method = [2] Local or when par. F-02 Operation
Method is [0] Linked to hand Auto, at the same time as the Keypad is in Hand mode.
AF-650 GP Programming Guide