AN-12 Terminal 53 Low Current
Range:
0.14 mA*
[0.00 - par. AN-13 mA]
AN-13 Terminal 53 High Current
Range:
20.00 mA*
[par. AN-12 - 20.00 mA]
AN-14 Terminal 53 Low Ref./Feedb. Value
Range:
0.000 Unit*
[-1000000.000 to par. AN-15]
AN-15 Terminal 53 High Ref./Feedb. Value
Range:
1500.000
[par. AN-45 to -1000000.000]
Unit*
AN-16 Terminal 53 Filter Time Constant
Range:
0.001 s*
[0.001 - 10.000 s]
3.8.3 AN-2# Analog Input 54
Parameters to configure the scaling and limits for Analog Input 2 (terminal 54)
AN-20 Terminal 54 Low Voltage
Range:
0.07 V*
[-10.00 - par. AN-21 V]
AN-21 Terminal 54 High Voltage
Range:
10.00 V*
[par. AN-20 - 10.00 V]
AN-22 Terminal 54 Low Current
Range:
0.14 mA*
[0.00 - par. AN-23 mA]
AN-23 Terminal 54 High Current
Range:
20.00 mA*
[par. AN-22 - 20.00 mA]
Function:
Enter the low current value. This reference signal should correspond to the minimum reference value, set
in par. F-52 Minimum Reference. The value must be set at >2 mA in order to activate the Live Zero Time-
out Function in par. AN-01 Live Zero Timeout Function.
Function:
Enter the high current value corresponding to the high reference/feedback set in par. AN-15 Terminal 53
High Ref./Feedb. Value.
Function:
Function:
Enter the analog input scaling value that corresponds to the maximum reference feedback value set in
par. AN-11 Terminal 53 High Voltage and par. AN-13 Terminal 53 High Current.
Function:
Enter the time constant. This is a first-order digital low pass filter time constant for suppressing electrical
noise in terminal 53. A high time constant value improves dampening but also increases the time delay
through the filter.
This parameter cannot be adjusted while the motor is running.
Function:
Enter the low voltage value. This analog input scaling value should correspond to the minimum reference
value, set in par. F-52 Minimum Reference. See also the section Reference Handling.
Function:
Enter the high voltage value. This analog input scaling value should correspond to the high reference/
feedback value set in par. AN-25 Terminal 54 High Ref./Feedb. Value.
Function:
Enter the low current value. This reference signal should correspond to the minimum reference value, set
in par. F-52 Minimum Reference. The value must be set at >2 mA in order to activate the Live Zero Time-
out Function in par. AN-01 Live Zero Timeout Function.
Function:
Enter the high current value corresponding to the high reference/feedback value set in par. AN-25 Ter-
minal 54 High Ref./Feedb. Value.
AF-650 GP Programming Guide