3.14 RS-## Resolver Interface

RS-50 Poles
Range:
2*
[2 - 2]
3
RS-51 Input Voltage
Range:
7.0 V*
[2.0 - 8.0 V]
RS-52 Input Frequency
Range:
10.0 kHz*
[2.0 - 15.0 kHz]
RS-53 Transformation Ratio
Range:
0.5*
[0.1 - 1.1]
RS-59 Resolver Interface
Activate the OPCRES resolver option when the resolver parameters are selected.
To avoid damage to resolvers par. RS-50 Poles – par. RS-53 Transformation Ratio must be adjusted before activating this parameter.
Option:
[0] *
Disabled
[1]
Enabled
134
Function:
Set the number of poles on the resolver.
The value is stated in the data sheet for resolvers.
Function:
Set the input voltage to the resolver. The voltage is stated as RMS value.
The value is stated in the data sheet for resolvers
Function:
Set the input frequency to the resolver.
The value is stated in the data sheet for resolvers.
Function:
Set the transformation ratio for the resolver.
The transformation ration is:
V Out
T ratio
=
V In
The value is stated in the data sheet for resolvers.
Function: