Backwater valve for wastewater with or without raw sewage

Advertisement

Available languages

Available languages

Prinzipdarstellung (Bsp. umpfix
oncrete floor with moisture protective
sheet
BWS
*
BWS
*
4
4
Installation with extension section Article Number 83071
The height of the groundwater sealing flange can be adjusted on-site if using the 83071 extension section. No more than 2 exten-
sion sections should be used to assure proper access to the backwater valve for service or repair. It may be required that the upper
section is shortened to meet on-site installation heights / requirements.
oncrete floor with waterproof concrete
BWS *
BWS *
4
4
3. Installation
®
F)
Tiles
Fliesen
Screed
Estrich
Insulation
Dämmung
Fliesen
Concrete slab
Betonboden
Estrich
Protective concrete
Schutzbeton
Dämmung
Moisture protective
Abdichtung
Betonboden
sub slab
Unterbeton
Schutzbeton
Abdichtung
Unterbeton
2
2
Fliesen
Estrich
Dämmung
Tiles
Fliesen
Betonboden
Estrich
Screed
Insulation
Dämmung
Waterproof concrete
Betonboden
floor
2
5
2
5
3
1
3
1
1
1
22
➀ KESSEL-Pumpfix
®
F, Staufix
FKA, Staufix
SWA, Controllfix
®
➁ Groundwater protection set
83023
➂ Extension section
(Article Number 83071)
➃ DN 100 intermediate section
with stainless steel counter flan-
ge (Article Number 27198)
➄ Elastomeric sealing barrier
(Article Number 27159)
®