Appendix
A.3 Data sets
A.3.5
3RW5 soft starter (slot 2)
A.3.5.1
Data set 68: Process image output (PIQ)
Read (r) and write (w) access to the process image output (PIQ) is possible.
Note
Note that data set 68 is overwritten by the cyclic process image in "Automatic" mode.
Byte
Data format
0
Unsigned8
2
0x02
4
Unsigned16
6
Unsigned16
Supported by SIRIUS 3RW50 soft starter
1)
Supported by SIRIUS 3RW52 soft starter
2)
Supported by SIRIUS soft starter 3RW55 and 3RW55 Failsafe
3)
130
Meaning
Coordination
[0x21] Write via acyclic bus channel – user program
Slot number
Length of data structure
Start position
50
x
x
x
x
SIRIUS 3RW5 PROFIBUS communication module
Equipment Manual, 02/2020, A5E35633549002A/RS-AC/003
3RW
52
55 / 55-F
1)
2)
3)
x
x
x
x
x
x
x
x