Appendix
A.3 Data sets
Object
Byte Bit Data format Parameters
No.
-
82
0
Unsigned16 Start button
84
0
Unsigned16 Start button
86
0
Unsigned16 Start button
88
0
Unsigned16 Start button
78
100
0
Unsigned8
83
106
0
Unsigned16 Timer Lighting
84
108
0
Unsigned8
85
109
2
Unsigned8
86
110
0
Unsigned8
1
Bool
3
Bool
94
112
0
Bool
168
Value range
[encoding]
[1 ... 65 534]
Functions 1
[1] Motor CW
[2] Motor CCW
[3] Motor CW - creep speed
[4] Motor CCW - creep speed
[65 534] No start type selected
(see Start button Functions 1)
Functions 2
(see Start button Functions 1)
Functions 3
(see Start button Functions 1)
Functions 4
Language
[0 ... 254]
[0] English
[1] German
[2] French
[3] Spanish
[4] Italian
[5] Chinese
[6] Portuguese
[254] Additional language
1 ... 60 min
Dark
[1 ... 60]
[0] Deactivated
Date format
[1 ... 3]
[1] MMDDYY
[2] DDMMYY
[3] YYMMDD
Time format
[1 ... 2]
[1] Time format: 12h
[2] Time format: 24h
Messages to
-
show
Error
[0 ... 1]
[0] Disable
[1] Enable
Warnings
[0 ... 1]
[0] Disable
[1] Enable
Display time
[0 ... 1]
[0] Disable
[1] Enable
Increment
-
-
-
-
-
5)
1 min
-
-
-
-
-
-
SIRIUS 3RW5 PROFIBUS communication module
Equipment Manual, 02/2020, A5E35633549002A/RS-AC/003
3RW5 HMI HF
1)
50 / 52
55 /
55-F
[D
]
2)
[D
]
3)
r
r/w
[1]
[1]
-
r/w
[65 534]
-
r/w
[65 534]
-
r/w
[65 534]
r/w
r/w
[0]
[0]
r/w
r/w
[5]
[5]
r/w
r/w
[1]
[1]
r/w
r/w
[1]
[1]
-
-
r/w
r/w
[1]
[1]
r/w
r/w
[1]
[1]
r/w
r/w
[0]
[0]

Advertisement