Appendix
A.3 Data sets
A.3.1
Byte arrangement
When data longer than one byte are stored, the bytes are arranged as follows ("big endian"):
A.3.2
Specifications
The following specifications apply in the data sets:
● Non-relevant (reserved) entries are not listed.
Fill these entries with "0" when writing.
● In data sets for parameters, codes are shown in square brackets "[...]". "[D
the default coding.
Object number (Obj. No.)
The object number (Obj. No.) is used for unique identification of all parameters available in
the 3RW5 soft starter. In the case of a parameterization error, the object number of the faulty
parameter is displayed in data set 92 of the 3RW5 soft starter (slot 2) (Page 135) or in data
set 92 of the 3RW5 HMI High Feature (slot 3) (Page 164) under "Faulty parameter number".
126
SIRIUS 3RW5 PROFIBUS communication module
Equipment Manual, 02/2020, A5E35633549002A/RS-AC/003
]" describes
x)