Ti interface

Installation drawing
4-40 unc × 2
Cover plate
Interface set-up LED
(digital interface only)
CAL button operation
Push and release (< 2 seconds) - Calibration (CAL) routine initiation / exit
Push and release (> 3 seconds) - Automatic Gain Control (AGC) initiation / exit
Push and hold during power 'Off / On' cycle - Restore factory defaults
Refer to 'Readhead LED diagnostics' and 'Ti LED diagnostics' for LED indications
ATOM linear installation guide
Dimensions and tolerances in mm
8
40
16
33.3
67
62
6 min
R> 20 Dynamic bend radius
R> 10 Static bend radius
CAL button access hole Ø2.4
Output signals
Digital
Function
Signal
Power *
A
Incremental
B
Reference mark
Z
Alarm
E
Set-up
Shield
Do not connect
Analogue
Function
Signal
Power *
Cosine
V
1
Incremental
Sine
V
2
Reference mark
V
0
Set-up
Remote CAL
CAL
Shield
Do not connect
*
 All power connections should be used either to minimise voltage drop down the cable or incorporate voltage sensing.
 The alarm signal can be output as a line driven signal or 3-state. Select the preferred option at time of ordering.
Pin
5 V
7, 8
0 V
2, 9
+
14
6
+
13
5
+
12
4
+
11
3
X
1
-
Case
-
10, 15
Pin
5 V
4, 5
0 V
12, 13
+
9
1
+
10
2
+
3
11
V
6
X
14
-
Case
-
7, 8, 15