Electrical Connections - Renishaw ATOM Series Installation Manual

Linear encoder systems
Table of Contents

Advertisement

Electrical connections

Grounding and shielding
FPC readhead
FPC cable
Shield
(recommended)
For more information on FPC contact your local Renishaw representative.
Cable readhead
Connector / interface
Shield
IMPORTANT: The shield should be connected to the machine earth (Field Ground).
NOTE: Maximum cable length between interface and customer electronics is 25 m for ACi and Ri and 50 m for Ti.
(Maximum length for Ti with 40 or 50 MHz clocked output is 25 m).
ATOM linear installation guide
ACi / customer
electronics
5 V
Output
signals
0 V
Customer
electronics
5 V
Output
signals
0 V
Recommended signal termination
Digital outputs
0 V
Interface
A B Z E+
Cable Z
= 120R
0
A B Z E−
Standard RS422A line receiver circuitry.
Capacitors recommended for improved noise immunity.
Analogue outputs
V
V
V
+
0
1
2
120R
V
V
V
0
1
2
Remote CAL operation
CAL
Remote CAL operation is possible via the CAL pin.
For applications where no interface is used, remote CAL operation is essential.
0 V
Customer
220 pF
electronics
120R
220 pF
0 V
45

Advertisement