Rtlf / Rklf Scale Applicator - Renishaw ATOM Series Installation Manual

Linear encoder systems
Table of Contents

Advertisement

RTLF / RKLF tape scale
(continued)

RTLF / RKLF scale applicator

Suitable for:
 RTLF tape scale, any length
 RKLF narrow tape scale, any length
Required parts:
 Appropriate length of scale
('RTLF installation drawing', page 5)
 End clamp kit, RKLF only (A-9523-4015)
 RGG-2 two part epoxy adhesive, RKLF only (A-9531-0342)
 Datum clamp, RTLF only (A-9585-0028)
 Loctite
®
435
, RTLF only (P-AD03-0012)
 Appropriate cleaning solvents
('Storage and handling', page 3)
 Readhead mounting bracket (see table below)
 Appropriate scale applicator (see table below)
 2 × applicator mounting screws
 2 × M2 × 6 screws, top mount applicator only
Readhead mounting bracket and scale applicator:
There are different versions of the applicator depending upon the scale and design of the readhead mounting bracket.
For more information on designing your bracket, contact your local Renishaw representative.
Slim applicator
In place of the readhead bracket
Mounting
Side mounting bracket
Applicable bracket
(A-9401-0103)
Customer-designed bracket
A-9402-0060
RTLF
A-6547-1947
RKLF
ATOM linear installation guide
or
('RKLF installation drawing', page 6)
Side mount applicator
Top mount applicator
In place of the readhead bracket
In place of the readhead
'L' mounting bracket
'L' mounting bracket
(A-9402-0037)
Customer-designed bracket
Customer-designed bracket
A-9402-0034
A-6547-1943
Optional parts:
 End cover kit, RTLF only (A-9585-0035)
 Renishaw scale wipes (A-9523-4040)
 Lint-free cloth
 Reference mark deselection stickers (A-9402-0049 for a sheet of 20)
 Loctite
®
(A-9402-0037)
A-9402-0028
A-6547-1939
435
dispensing tip (P-TL50-0209)
10

Advertisement