Rtlf / Rklf Tape Scale; Rtlf Installation Drawing - Renishaw ATOM Series Installation Manual

Linear encoder systems
Table of Contents

Advertisement

RTLF / RKLF tape scale

RTLF installation drawing

For dimensioned cabled and FPC readhead drawings see
1.02 ±0.25
4.5
Overall length (with optional end covers) = Measuring length + 50 mm
Scale length (with optional end covers) = Measuring length + 13 mm
Scale length (without end covers) = Measuring length + 6 mm
For detailed installation drawings refer to
www.renishaw.com/atomdownloads
ATOM linear installation guide
page 33
and
page
34.
Set-up LED
Reference mark
50
12
Datum clamp
(A-9585-0028)
(page 12)
(Pitch tol. ±1°)
0.36
40 µm version
( Yaw tol. ±1°)
0.36
20 µm version
( Yaw tol. ±0.5°)
0.18
50
Readhead / scale orientation
FPC ribbon cable
Forward direction of readhead
relative to scale
Dimensions and tolerances in mm
(Roll tol. ±1°)
0.22
Reference mark
Scale datum edge
8
Scale thickness (including adhesive) 0.41
Calibration rideheight:
2.5 ±0.08
(40 µm version)
2.5 ±0.04
(20 µm version)
Operating rideheight:
2.5 ±0.11
(40 µm version)
2.5 ±0.055
(20 µm version)
5