Rklf Installation Drawing - Renishaw ATOM Series Installation Manual

Linear encoder systems
Table of Contents

Advertisement

RTLF / RKLF tape scale
(continued)

RKLF installation drawing

For dimensioned cabled and FPC readhead drawings see
Offset 2.02 ±0.25
End clamp
(Pair A-9523-4015)
Reference mark
Overall length = Measuring length + 70 mm
Scale length = Measuring length + 40 mm
ATOM linear installation guide
page 33
and
page
34.
Set-up LED
50
FPC cable
(Pitch tol. ±1°)
0.36
Forward direction of readhead
40 µm version
( Yaw tol. ±1°)
0.36
20 µm version
( Yaw tol. ±0.5°)
0.18
50
Readhead/scale orientation
relative to scale
Reference mark
Scale datum edge
6
15
30
Scale thickness 0.15
(including adhesive)
Calibration rideheight:
2.5 ±0.08
2.5 ±0.04
Operating rideheight:
2.5 ±0.11
2.5 ±0.055
Dimensions and tolerances in mm
(Roll tol. ±1°)
0.22
13
(40 µm version)
(20 µm version)
(40 µm version)
(20 µm version)
6