7.10.8.3

Reduced acceptance test

A complete acceptance test is only necessary following first commissioning. An acceptance
test with a reduced scope is sufficient for expansions of safety functions.
The reduced acceptance tests must be carried out separately for each individual drive, as far
as the machine allows.
Reduced acceptance test for function extensions
Table 7- 39
Scope of the acceptance test depending on specific measures
Measure
Replacing the Control Unit or
the Power Modules.
Hardware replacement of
safety-related distributed I/O
devices (e.g. emergency off
switch).
Firmware - upgrading the
Control Unit.
Functional expansion of the
machine (additional drive).
Functional expansion of a
drive (e.g. enable STO).
Transfer of inverter
parameters to other identical
machines by means of series
commissioning.
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
Documentation
Supplement:
Hardware data
Configuration
Firmware Versions
Supplement:
Hardware data
Configuration
Firmware Versions
Supplement:
Version data
New safety functions
Supplementary safety functions
for each drive and function table.
Supplement to the safety
functions for each drive and
function table.
Supplement to the machine
description (checking of the
firmware versions).
7.10 Safe Torque Off (STO) safety function
Acceptance test
Function test
Completion of the certificate
Yes.
Supplement:
New checksums and
countersignature
Partially.
No.
Limitation to
replaced
components.
Yes.
Supplement:
New checksums and
countersignature.
Yes.
Supplement:
Testing the
New checksums and
additional functions.
countersignature.
Yes.
Supplement.
Testing the
New checksums and
additional functions.
countersignature.
No.
No, if data are identical
(checking of checksums).