Run Circuit Operation Legend; Charging Circuit Operation - Husqvarna Z400 Series Service Manual

Zero-turn mower
Table of Contents

Advertisement

ELECTRICAL

Run Circuit Operation Legend

A1)
Fuse Block Assembly
A2)
Hour Meter
F1)
Main 20A Fuse
F3)
Clutch/Starter 15A Fuse
G1)
Battery
G2)
Voltage Regulator
K1)
Starter Relay
K2)
Motion Control Lever Relay
M1)
Starter Motor
S1)
Seat Switch
NOTES:
• In Figure 6-52 on page 6-38, PTO switch (S5) is
shown in the off position and seat switch (S1) is
shown in the released position.
• In Figure 6-53 on page 6-39, left parking brake
switch (S2) and right parking brake switch (S3) are
shown in the parked position.

Charging Circuit Operation

The charging system regulates the battery voltage when
the engine is running. When the engine is running and
the key switch is in the RUN position, the voltage
regulator coverts the stator output voltage from AC to DC
voltage. The voltage regulator uses the DC voltage to
maintain the battery charge.
G1
BLK
X11
A1)
Fuse Block Assembly
F1)
Main 20A Fuse
G1)
Battery
S2)
Left Parking Brake Switch
S3)
Right Parking Brake Switch
S4)
Key Switch
S5)
Power Take-Off (PTO) Switch
SP3)
Splice S3
SP4)
Splice S4
V1)
Clutch Diode
X2)
Left Parking Brake Interconnect
X3)
Hour Meter Interconnect
X4)
Engine Connector
RED
1
X9
M1
RED
G2)
Voltage Regulator
M1)
Starter Motor
X4)
Engine Connector
Figure 6-54
X7)
X9)
X10)
X11)
X12)
X13)
X14)
Y2)
Y3)
A1
A1
A2
F1
X9)
X11)
6-40
Right Parking Brake Interconnect
Battery Positive Interconnect
Battery Ground Interconnect
Engine Ground
Clutch Interconnect
Fuel Shutoff Solenoid Interconnect
Ignition Coil – Primary Side
Electric Clutch
Fuel Shutoff Solenoid
1
X4
GRY
G2
Battery Positive Interconnect
Engine Ground
Z400 Series
HUS1138

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z448Z454Z460Z454xZ460x

Table of Contents