brAKe cONTrOL AND TeMPerATUre DeTecTION

4.4 brake control and temperature detection
Figure 24:

4.4.1 Specification and connection of the brake / relay control

Features of the control
The control, parameterization and reading of the feedback inputs of the brake is carried
out via the integrated safety module. Corresponding wiring and parameterization sug-
gestions are described in the safety manual type 5.
Name
function
Dc output voltage
Maximum braking current
Others
Table 29:
NOTICE
54
X1c
PIN
1
2
3
2
4
6
8
10
4
5
1
3
5
7
9
6
7/8
9
10
Assignment of the terminal block X1C
safely control one brake/relay
control together two single brakes/relays; it must be the same brake/relay twice.
Internal brake feedback without additional wiring or external via two digital brake
inputs.
Power reduction through pulse width modulated control.
Rapid demagnetization with a counter voltage of 27.5 V, maximum every 5 s
Current monitoring
Specification of the brake control
Using a brake
► Choose the input voltage tolerance of the brake corresponding to the
tolerance of the output voltage.
Name
Notes
BR+
Brake control / output
BR-
Brake control / output
0V
for supply of the feedback inputs
P24Vin - 0.5 V / max. 1 A
24Vout
(BR+ and 24Vout in addition 2 A)
DIBR1
feedback input for
brake control
DIBR2
feedback input for
brake control
reserved
TA1
Temperature detection / input+
TA2
Temperature detection / input-
BR+ (X1C.1); BR- (X1C.2)
Output for control one/two brake(s) or relay(s)
Minimum P24Vin -1,2 V
Maximum P24Vin
one brake: 2 A
two brakes: 2 x 1 A
Internal free-wheeling path; internal filter cir-
cuit;not short-circuit proof