Code - Balluff BVS HS-P Series Operation Manual

Industrial handheld barcode readers
Table of Contents

Advertisement

Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
3
Configuration Using Barcodes

3.8.19 Code 128

Code 128
Enable/Disable
C8EN01(CR
Expand Code
128 to Code 39
C8C301(CR
Code 128
Check
Character
Transmission
C8CT01(CR
www.balluff.com
The following options apply to the Code 128 symbology.
When disabled, the reader will not read Code 128 barcodes.
Code 128 = Enable
This feature enables/disables expansion of Code 128 labels to Code 39 labels.
DEFAULT
Code 128 to Code 39 = Expand
Enable this option to transmit the check character along with Code 128 barcode data.
DEFAULT
Code 128 Check Character Transmission =
Send
C8EN00(CR
Code 128 = Disable
DEFAULT
C8C300(CR
Code 128 to Code 39 = Don't Expand
C8CT00(CR
Code 128 Check Character Transmission =
Don't Send
119