Input Connections (Default)
Use green 2-position connectors on control board to add any
necessary inputs. (Figure 15)
NOTE: Inputs can be customized.
Input 1: Activation 1
Momentary contact closure of this input cycles door through an
automatic open / close cycle. Tied to Open Delay 1.
Input 2: Activation 2
Momentary contact closure of this input cycles the door through an
automatic open / close cycle. Tied to Open Delay 2.
Input 3: Toggle / Executive Mode
Momentary contact closure of this input sends a closed door to
open position or an open door to closed position.
Input 4: Blow Closed
Continuous contact closure of this input puts operator in a passive
closer mode, where door functions as a typical door closer and
accepts no activations. Once contact is removed, unit goes back to
operator mode.
Input 5: Blow Open
Continuous contact closure of this input triggers operator to go
to open position and stay there until contact is removed. If door is
pulled away from open position, operator will go back to open from
any point.
Input 6: Hold Open
Continuous contact closure of this input triggers operator to go
to open position and stay there until contact is removed. If door is
pulled away from open position, operator will close completely and
reopen to open position and stay in open position until contact is
removed.
10
6300 Series Programming Instructions
Figure 15
Input 7: Obstruction 1
Contact closure of this input while door is open or closing triggers
operator to return to open position. This is used in conjunction with
presence sensors mounted to closing side of a door to prevent door
from hitting an obstruction.
Input 8: Obstruction 2
Contact closure of this input while door is closed or opening
triggers operator to stall. If contact is not removed after 10 seconds
of closure, operator will return to closed position. This is used in
conjunction with presence sensors mounted to opening side of a
door to prevent door from hitting an obstruction.
Input 9: Security Override
Continuous contact closure of this input triggers operator to disable
Input 2 / Activation 2. This is typically used for switching off an
outside wall plate.
Input 10: Spare input
Input 11: Spare input
Copyright © 2019, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or