6300 Series Programming Instructions
Output Connections (Default)
Use green 2-position connectors on control board to add any
necessary outputs, such as electric strikes, mag locks, exit devices,
door open position output, etc. (Figure 16)
NOTE: Relay outputs can be customized.
Relay 1 Output: Normally open relay that closes for 3 seconds after
an activation to open.
Relay 2 Output: Normally open relay that closes when door is in
open position.
Normally Open: 24VDC output up to 1.3 Amp draw that closes after
an activation to open.
Normally Closed: 24VDC output up to 1.3 Amp draw that opens for
5 seconds after an activation to open.
Copyright © 2019, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0015-020 Rev 1 11/19