Step 5: Adjust Closing Position Magnet (See Fig. 3) - With door in
the closed position, use finger to slide Closed Position
Magnet so it aligns directly with the Reed Switch.
Open Position
Magnet
Position Ring
Step 6: Adjust Open Position Magnet - Use fingers to slide Open
CONCEALED WIRING
Thread conduit fitting(s) into backplate as shown. A second
conduit fitting is required for low voltage control wiring. CHECK
LOCAL CODES. Pull conduit out of header and attach to conduit
fittings before mounting
incoming ground wire to backplate with ground screw as
illustrated in "Surface Wiring" illustration to the Right.
Low Voltage
Control
Wiring
Ground Wire Connection – Ground wire must be secured to backplate
under head of (green) ground screw nearest to "T1" Power Input
Terminal. Screw labeled "GND".
Terminal
COM
Common power lead
HOT
Hot power lead
25
Circuit Breaker
24
Switch
23
Circuit Breaker
Common connection to Circuit Breaker /
22
Inverter
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2010, 2013 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
3. Electrical Connections and Final Setup Continued
Reed Switch
Closed Position
Magnet
Figure 3
Input Power Configurations
Operator to door frame.
Incoming
Power
Description
Position Magnet 180° from Open Position Magnet.
Step 7: Flip Breaker Switch to "RESET" to turn power on. Jump
terminals 1 and 2 (as shown in Fig. 2) to activate door. Note
open position of the door. Allow door to close.
Step 8: Use finger to readjust the Open Position Magnet to desired
door open position.
Step 9: Repeat Step 7 to verify door open position.
Step 10: Make all connections necessary for any accessories to the
4-position Accessory Terminal (see Pages 9 - 11).
Step 11: Make necessary adjustments to inverter (see Page 9).
Replace cover and cover screws.
SURFACE WIRING
An optional bracket is provided for use with surface wiring.
Remove the two cable clamps screws and slip the bracket under
the cable clamps. Push the cable clamp screw through the
bracket holes and tighten. ½" conduit fittings can now be
Attach
installed on the bracket. Attach incoming ground wire to
backplate with ground screw as illustrated below.
"T1" Power
Input
Terminal
Cable
Clamps
Page 8
Optional Bracket
(for surface wiring)
Ground
Screw
(Green)
Breaker Switch
T1 Terminal
Block
25
HOT
COM
80-9357-0001-020 (09-13)
ASSA ABLOY
Ground
Power
Lead
Leads
Conduit
by Others
(from top)
24
23
22