Number
Cause
of Flashes
1
24VDC power error too high or
2
too low.
Error occurred during Learning
3
process.
4
5
6
7
Motor overheating.
8
9
TEMP connector not plugged in. Plug in TEMP connector on backplate.
12
Error Codes for RED POWER LED Flashes
Solution
Reset back to factory defaults by pressing and holding POWER button until all
LEDs light up then release. Unit will reset and CLOSE button will be flashing.
Repeat step to set Open and Closed Positions and Learn process.
Check incoming voltage to power supply and from power supply to board.
If door hit obstruction, reset to factory defaults by pressing and holding POWER
button until all LEDs light up, then release. Repeat steps to set Open and Closed
Positions and Learn process.
If door did not hit obstruction, inspect hinges or door / frame for excessive wear,
misalignment, etc. Replace worn components and repeat steps to set Open and
Closed Positions and Learn.
Ensure all harnesses are plugged in and secure - focus on motor wires.
Ensure all harnesses are plugged in and secure - focus on harnesses attached to
backplate.
Ensure all harnesses are plugged in and secure - focus on main board harnesses.
Ensure all harnesses are plugged in and secure - focus on harnesses attached to
backplate.
Copyright © 2019, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
6300 Series Programming Instructions
80-9363-0015-020 Rev 1 11/19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents