Delayed Egress
ED4000, ED5000 Series Exit Device
Installation Instructions

Wiring Layout: Input/Output Wiring Descriptions

6
J2 Connector
(See Figure 5 on next page)
Pin Number
10
12
11
13
NC
3
8
6
NOTE: ElectroLynx QC8 Hinge is only required if all eight wires are used. When DPS and any
other wiring options are on the 4-pin connector, the hinge is NOT required.
NOTE: Secure and Alarm Relay contacts are rated max load 1A @24VDC.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2006, 2010, 2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Input/Output
Wire Color
Input
Black
Input
Red
Output
White
Output
Green
EGND
Orange
Output
Blue
Input
Brown
Input
Yellow
Description
24VDC Power Supply (-Circuit Ground)
24VDC Power Supply (+Positive)
Secure Relay Output - Normally Open (NO)
contact. Power off - contact is open
Powered/armed - Relay energizes contact
closes. After 15 or 30 seconds delay when
device releases, the relay de-energizes, contact
opens (same as Power off state).
Secure Relay Output - Normally Closed (NC)
contact. Power off - contact is closed.
Powered/armed - Relay energizes, contact
opens. After 15 or 30 seconds delay when
device releases, relay de-energizes, contact is
closed (same as Power off state).
Earth Ground connection to PCB mounting plate
via ring terminal
Alarm Relay Output - J5 jumper Selectable
NO/NC contact that changes state when alarm
cycle has been activated. Default shipped
position - jumper is on NO contact setting.
Power off - contact is NO or NC as per jumper
selection.Powered/armed - Relay energizes
contact reverses state. When alarm cycle is
activated - Relay de-energizes (same as Power
off state).
Remote Reset Input - Momentary input from
key switch, pushbutton, etc. Will release device
for 5, 10, 20, or 40 seconds for egress or
ingress and also reset device when in bypass or
alarmed state.
Remote Bypass Input - Momentary input
from key switch, pushbutton, etc. Will maintain
device in an unlocked state for normal device
operation. Device must be rearmed by resetting
from key switch on device or remote reset.
9
8-Pin
ElectroLynx
Connector
Pin Number
1
2
3
4
5
6
7
8
FM209 10/20