6000 Series Programming Instructions
Input Connections (Default)
Use green 2-position connectors on control board to add any
necessary inputs. (Figure 19)
NOTE: Inputs can be customized.
Inputs: The operator has several inputs which may be wired to
external switches, sensors, and dry contacts. The function of each input
is selectable depending on the needs of the installation.
The inputs are labeled 1-8 like the wiring terminal blocks on the
operator hardware.
Click Restore Defaults to set the input and output functions to factory
default, if needed. Be sure to click Save after making changes.
Activation 1
Momentary contact closure of this input cycles door through an
automatic open / close cycle. Tied to Open Delay 1.
Activation 2
Momentary contact closure of this input cycles the door through an
automatic open / close cycle. Tied to Open Delay 2.
Executive Mode
When the door receives activation signal it opens and remains open
until either a second signal is received or the door is manually moved
in closing direction.
Emergency Interface Relay
This is an input from a fire panel. The door closes and ignores any
activation input until the signal is discontinued.
Blow Open
If 3-Position switch is in On position, the door opens when signal is
received from alarm system allowing air or smoke to flow through
opening. The door will stay open until signal from alarm system is
stopped. If the door is pulled away from open position, operator will
go back to open.
Blow Open Override
With 3-Position switch in On or Off position, the door opens at set
position until power is turned off.
Obstruction 1
Contact closure of this input while door is closing triggers operator to
return to open position. This is used with presence sensors mounted
to closing side of a door to prevent door from hitting an obstruction.
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1043-020 Rev 1 05/21
Input Connectors
Figure 19
Obstruction 2
Contact closure of this input while door is opening triggers operator
to stall. If contact is not removed after 10 seconds of closure,
operator will return to closed position. This is used with presence
sensors mounted to opening side of a door to prevent door from
hitting an obstruction.
Outside Push Button Disable
When this contact is closed, the outside push button is disabled
(connected to ACTIVATION 2 inputs(s)).
BEA 585 Presence Sensor
A BEA type 585 presence sensor may be connected to the "SENSOR"
connector on the top circuit board of the operator using cable
supplied with sensor. The sensor must be attached to the frame
according to the BEA factory instructions and can be powered with
a separate power supply or with the power supply built into the
6000 operator. No additional configuration is required. See the
installation instructions for more detail.
BEA Sensor