5

Wiring Layout: Input/Output Wiring Descriptions

J2 Connector
(Figure 5)
Pin Number
1
2
3
4
5
6
7
8
NOTE:
• Pins 5-8 are negative (-) outputs. Use with LEDs and audibles (horns, sirens, etc.).
See wiring diagrams (Sections 9 through 14) for details.
• Cap all unused wires with enclosed wire nuts.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Input/Output
Wire Color
Input
Black
Input
Red
Input
Brown
Input
Yellow
Output
Orange
Output
Blue
Output
Green
Output
White
Old Board
New Board
Figure 5
Description
24VDC Power Supply (-Circuit Ground)
24VDC Power Supply (+Positive)
Remote Reset Input - Momentary input from
key switch, pushbutton, etc. Will release device
for 20 seconds for egress or ingress and also
reset device when in bypass or alarmed state.
Remote Bypass Input - Momentary input from
key switch, pushbutton, etc. Will maintain device
in an unlocked state for normal device operation.
Device must be rearmed by resetting from
remote reset on device.
Alarm Relay Output - Normally open contact
that changes to normally closed when device
alarm cycle has been activated.
Alarm Relay Output - Normally closed contact
that changes to normally open when device
alarm cycle has been activated.
Secure Relay Output - Normally closed contact
that changes to normally open when device has
released.
Secure Relay Output - Normally open contact
that changes to normally closed when device
has released.
To Device; Factory Wired
To Device; Factory Wired
7
ElectroLynx
Connector
Pin Number
1
2
7
8
5
6
4
3
Black
Negative
Red
Positive
White
Remote Reset
Blue
Remote Bypass
Brown
Secure Relay Output (NO)
Orange
Secure Relay Output (NC)
Yellow
Alarm Relay Output (NO)
Violet
Alarm Relay Output (NC)
Black
Negative
Red
Positive
Brown
Remote Reset
Yellow
Remote Bypass
Orange
Alarm Relay Output (NO)
Blue
Alarm Relay Output (NC)
Green
Secure Relay Output (NC)
White
Secure Relay Output (NO)
FM209 10/18