Input Power Configurations
1.
Thread conduit fitting(s) into backplate.
Concealed Wiring (Figure 26)
Surface Wiring (Figure 27)
NOTE:
• A second conduit fitting is required
for low voltage control wiring.
• Check local codes.
2.
Pull conduit out of header and attach to
conduit fittings before mounting unit.
3.
After installing operator, attach incoming
ground wire to backplate with ground
screw as illustrated. (Figure 27)
NOTE: Ground wire must be secured to
backplate under head of (green) ground
screw.
Figure 28
12
Figure 27
Copyright © 2016, 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2020-01-27
5700 Series Power Operator
Figure 26
Terminal
Description
COM
Common power lead
HOT
Hot power lead
25
Circuit Breaker
24
Switch
23
Circuit Breaker
Common connection to
22
Circuit Breaker / Inverter
80-9357-0008-020 Rev 6 01/20