Toshiba V Series User Manual page 131

Sequence controllers
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

Pulse output
Other output
Current consumption
*1: Single axis independent operation command
The startup time for interpolation operation is 3ms or less.
When more than one axis is enabled, the maximum startup time is the sum of the
startup time of each axis. The priority in multiple axes operation is X, Y, Z and U.
6F8C0836
Item
Mode
Output
specification
ON/OFF delay
Signal name
Output method
ON/OFF delay
Internal power
supply
External power
supply
2.3 I/O Module Specification
MC614
CW/CCW (positive/negative direction pulse)
PLS/DIR (pulse/direction)
Differential output (equivalent to RS422) - Max.
30mA
200ns or less
Deviation counter clear pulse output
Servo ON output
Open collector
5 - 24Vdc - max.50mA
500 µ s or less
Approx. 700mA
Approx. 200mA