<HOW TO CHECK THE THERMISTOR>
Select the Head you replaced in [THERMISTOR CHK]
menu and check if the temperature displayed on the LCD
is not too low (0 degrees) or too high (100 degrees).
<HOW TO CLEAR THE HEAD INFORMATION>
After THERMISTOR CHECK and HEAD ALIGNMENT,
clear the HEAD INFORMATION from the SERVICE
MENU > HISTORY MENU > HEAD GROUP.
* The Head No. becomes [HEAD 1], [HEAD2], [HEAD3]
from the Head at the left end in order.
SERVICE MENU
THERMISTOR CHK
SERVICE MENU
HISTORY MENU
[
HISTORY MENU
HEAD GROUP
3-10
THERMISTOR CHK
BOARD: 25 C/77 F
THERMISTOR CHK
BOT. : 25 C/77 F
THERMISTOR CHK
HEAD1: 25 C/77 F
THERMISTOR CHK
HEAD6: 25 C/77 F
]
HEAD GROUP
CLEAR H1
HEAD GROUP
CLEAR H2
HEAD GROUP
CLEAR H3
HEAD GROUP
CLEAR H4
HEAD GROUP
CLEAR H5
HEAD GROUP
CLEAR H6
HEAD GROUP
CLEAR ALL
[
]
[
]
[
]