11)
Close the Cartridge-Slot cover, and press the
[ENTER] key.
The Supply Pumps will be set to Open state
automatically.
Fill the tube between the maintenance liquid cartridge
2
and the tray with the maintenance liquid.
1)
Select [SERVICE MENU] > [I/S MENU] > [I/S
CONTROL] > [M-LIQUID PUMP] > [CLOSE].
And press the [ENTER] key.
2)
Select [SUPPLY], and press the [ENTER] key to
rotate the Maintenance Liquid Pump for 30 sec.
The maintenance liquid will be supplied to fill the
tube between the maintenance liquid cartridge and
the tray.
3)
The screen shown in the figure is displayed while the
Maintenance Liquid Pump is working. Select [OPEN]
and press the [ENTER] key to stop the Maintenance
Liquid Pump with the Open state.
There is no need to remove the maintenance
liquid cartridge.
SERVICE MENU
I/S MENU
I/S MENU
I/S CONTROL
I/S CONTROL
M-LIQUID PUMP
M-LIQUID PUMP
CLOSE
M-LIQUID PUMP
CLOSE
M-LIQUID PUMP
SUPPLY
SUPPLY
CLOSE
SUPPLY
OPEN
7-27
[
] [
]
[
] [
]
[
] [
]
[ENTER]
[
]
[ENTER]
[
]
[ENTER]