Even though the machine
carries out the regular
movement, the output of
0172
Supply Pump 3 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0173
Supply Pump 4 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0174
Supply Pump 5 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0175
Supply Pump 6 Sensor
does not reach the
expected value.
Even though the machine
carries out the regular
movement, the output of
0180
Maintenance Liquid Pump
Sensor does not reach the
expected value.
Thermistor under the BED
0190
has a problem.
Head 1 is abnormally hot.
0200
Head 1 temperature has
reached 58°C and above.
Head 2 is abnormally hot.
0201
Head 2 temperature has
reached 58°C and above.
Head 3 is abnormally hot.
0202
Head 3 temperature has
reached 58°C and above.
Head 4 is abnormally hot.
0203
Head 4 temperature has
reached 58°C and above.
Head 5 is abnormally hot.
0204
Head 5 temperature has
reached 58°C and above.
Head 6 is abnormally hot.
0205
Head 6 temperature has
reached 58°C and above.
Supply Pump 3 Motor has a problem.
Supply Pump 3 Sensor has a problem.
Supply Pump 3 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 4 Motor has a problem.
Supply Pump 4 Sensor has a problem.
Supply Pump 4 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 5 Motor has a problem.
Supply Pump 5 Sensor has a problem.
Supply Pump 5 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Supply Pump 6 Motor has a problem.
Supply Pump 6 Sensor has a problem.
Supply Pump 6 Magnet has dropped out.
Wiring or Flexible Cable has short circuitted
or cut-line.
Pump Board has a problem.
Servo Board has a problem.
Maintenance Liquid Pump Motor has a
problem.
Maintenance Liquid Pump Sensor has a
problem.
Maintenance Liquid Pump Magnet has
dropped out.
Wiring or Flexible Cable has short circuitted
Device has a problem.
Thermistor Cable has short circuited or cut-
line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Wiring of Head Heater has a problem.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Thermistor (Head) has a problem.
Flexible Cable has short circuitted or cut-line.
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 3 Magnet
Supply Pump 3 Motor replacement
Supply Pump 3 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 4 Magnet
Supply Pump 4 Motor replacement
Supply Pump 4 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 5 Magnet
Supply Pump 5 Motor replacement
Supply Pump 5 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Check Supply Pump 6 Magnet
Supply Pump 6 Motor replacement
Supply Pump 6 Sensor replacement
Wiring or Flexible Cable replacement
Pump Board replacement
Servo Board replacement
Check Cable connection of Servo Board
Check Cable connection of Junction Board
Maintenance Liquid Pump Motor replacement
Maintenance Liquid Pump Sensor replacement
Wiring or Flexible Cable replacement
Servo Board replacement
Thermistor replacement
Check Cable connection
Heater Board replacement
Check Flexible Cable connection around Head
Check Cable connection around Heater
Head replacement
Check Flexible Cable connection around Head
Head replacement
Check Flexible Cable connection around Head
Head replacement
Check Flexible Cable connection around Head
Head replacement
Check Flexible Cable connection around Head
Head replacement
Check Flexible Cable connection around Head
Head replacement
6-14