Roland Advanced Jet AJ-1000 Service Notes page 117

Hide thumbs Also See for Advanced Jet AJ-1000:
Table of Contents

Advertisement

Turn on the MainPower and then turn on the Sub Power
7
while pressing the Left, Right and Down keys to enter the
Service Mode.
Select [SERVICE MENU] > [SUB MENU] > [REPLACE
8
TUBE] > [PREPARE], and press the [ENTER] key.
Operation of preparation for Tube replacement will
start.(about 1 minute)
The Supply Pumps rotate to return the ink in the Sub
Tank to the Ink Cartriadge. When the Sub Tank becomes
empty, the Supply Pumps stop with the Close state. The
Pressure Pump is also closed.
When [REMOVE TUBE FROM HEAD] displayed on the
9
LCD, perform the following procedures.
1. Disconnect the Ink Tube from the Ink Damper.
2. Wipe off the ink splattered to the tube.
3. Hook it to the tape as well as Flexible Cable.
Press [ENTER] key.
10
Preparation for Tube replacement is continued.(about 1
minute)
The Pressure Pump starts rotating to return the ink in the
Sub Tank through the Ink Damper to the Sub Tank. When
the ink goes back, the Pressure Pump stop with the
Close state and the Head goes up.
When the preparation for Tube replacement is finished,
[REPLACE TUBE PREPARE] is displayed on the LCD
[
], [
MENU
SERVICE MENU
SERVICE MENU
SUB MENU
REMOVE TUBE
Ink Tube
REPLACE TUBE
PREPARE
3-32
], [
] + POWER ON
[MENU] key
SUB MENU
REPLACE TUBE
REPLACE TUBE
PREPARE
NOW PROCESSING...
FROM HEAD
Tape
[
]
[ENTER]

Advertisement

Table of Contents
loading

Table of Contents