Product overview
1 Time
Fig. 3 Input and output switching characteristics in normal status
Proximity switch reaction times
Switch on
t
Depending on p1, flow control valve set-
1
ting and system volume at p2.
t
Maximum of 4 s after signal at V1.
S1.1
t
Maximum of 4 s after signal at V2.
S2.1
t
After signal at V1 and V2. Depending on
S3.1
p1, flow control valve setting and system
volume at p2.
1) After the reaction time the signals are applied statically. The maximum specified reaction times must be considered in the diagnostics.
These reaction times are normally shorter.
Tab. 5 Proximity switch reaction times
Switch-through pressure
There is a flow control screw in the cover of the product. The flow control screw can be used to gener-
ate a gradual pressure build-up of output pressure p2 è 14.5 Filling flow.
The flow rate and thus the pressure rise can be adjusted by turning the flow control screw. When the
output pressure p2 reaches about 50 % of the operating pressure p1, the maximum flow rate perform-
ance is enabled.
10
1)
Switch off
t
S1.2
t
S2.2
t
S3.2
Maximum of 4 s after signal drop at V1.
Maximum of 4 s after signal drop at V2.
Maximum of 5 s after signal drop at V1
and V2. Depending on system volume at
p2.
Festo — MS6-SV-...-D-10V24 — 2019-05b