Festo MS6-SV D-10V24 Series Instructions Manual page 9

Soft start/quick exhaust valve
Hide thumbs Also See for MS6-SV D-10V24 Series:
Table of Contents

Advertisement

Product overview
V1
V2
S1
Voltage [V]
Switching position
0
0
1
24
0
0
0
24
1
24
24
0
24
24
0
Tab. 3 Switching logic
Function
Symbol
Tab. 4 Circuit symbol for the function
Switching behaviour
Switching behaviour of the product's internal valves. The normally exhausted position is sensed by
the proximity sensors. Switching logic è Tab. 3 Switching logic.
Festo — MS6-SV-...-D-10V24 — 2019-05b
S2
S3
MS6-SV-D
Status
1
1
Normal position
Port 1 blocked, passage from port 2 to 3 opened.
1
1
Normal position, optional testing condition
Tab. 6 Recommendation for activation and diagnostics.
è
Port 1 blocked, passage from port 2 to 3 opened.
0
1
Normal position, optional testing condition
Tab. 6 Recommendation for activation and diagnostics.
è
Reduced flow rate via flow control valve from port 1 to 2, pas-
sage from port 2 to 3 opened.
0
4
Switching position 1.
Reduced flow rate over flow control valve from connection 1 to
2, passage from connection 2 to 3 blocked.
0
0
Switching position 2.
Full flow from connection 1 to 2, passage from connection 2 to
3 closed.
Function
Soft-start/quick exhaust valve, electrically actu-
ated.