3 Parameter
3.3 Parameters for DC1...E1 variable speed starters
Modbus-
Para-
Parameter name
Register
meter
169
P-41
PID1 Kp
170
P-42
PID1 Ti
171
P-43
PID1 Mode
172
P-44
PID1 Set Point 1 Source
173
P-45
PID1 Set Point Digital
174
P-46
PID1 Feedback 1 Source
175
P-47
AI2 Signal Range
176
P-48
t-Standby
177
P-49
PID1 WakeUpLevel
178
P-50
CAN0 Baudrate
179
P-51
T-Memory Enable
180
P-52
ParameterAccess
181
P-53
Action@Communication Loss
182
P-54
RO1 Hysteresis
183
P-55
RO1 Switch-On Delay
188
P-60
Motor Control Mode
189
P-61
Motor Identification
190
P-62
MSC Gain
191
P-63
I-CurrentLimit
192
P-64
Motor Stator Resistance R1
193
P-65
Motor Stator Inductance d-Axis
194
P-66
Motor Stator Induktivität q-Achse
195
P-67
f-DCBremse@Stopp
196
P-68
DC-Brake Current
56
Access
rw/ro
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Modbus RTU for variable frequency drive DA1, DC1, DE1 09/16 MN040018EN www.eaton.com
Scaling
RUN/
STOP
RUN
10 ≙ 1.0
RUN
300 ≙ 3.00 s
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
300 ≙ 3.00 s
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
1 ≙ 1
RUN
300 ≙ 3.00 s
RUN
1 ≙ 1
RUN
300 ≙ 3.00 s
RUN
10 ≙ 1.0 %
RUN
10 ≙ 1.0 %
RUN
RUN
RUN
RUN
3000 ≙ 50.0 Hz
RUN
10 ≙ 1.0 %
Value range
0,1 - 30
0.0 s - 30.0 s
0 - 1
0 - 1
0 - 1
0 - 3
0 - 6
0.0 s - 25.0 s
0 - 1
0 - 3
0 - 1
0 - 1
0 - 4
0 - 1
0.0 s - 250.0 s
0 - 4
0.0 s - 250.0 s
0.0 % - 200.0 %
0.1 % - 175 %
0.00 Ω - 655.35 Ω
0.0 mH - 6553.5 mH
0.0 mH - 6553.5 mH
0.0 Hz - P-01
0,0 % - 100.0 %
Data
format
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16
U16