Eaton PowerXL DA1 Communications Manual page 50

Modbus rtu for variable frequency drives/variable speed starters
Hide thumbs Also See for PowerXL DA1:
Table of Contents

Advertisement

3 Parameter
3.1 Parameters for DA1 variable frequency drives
Modbus
Para-
Parameter name
register
meter
301
P3-01
PID1 Kp
302
P3-02
PID1 Ti
303
P3-03
PID1 Kd
304
P3-04
PID1 Mode
305
P3-05
PID1 Set Point 1 Source
306
P3-06
PID1 Set Point Digital
307
P3-07
PID1 Output upper Limit
308
P3-08
PID1 Output lower Limit
309
P3-09
PID1 Output LimitSelect
310
P3-10
PID 1 Feedback 1 Source
311
P3-11
PID1 Error Ramp
312
P3-12
PID1 Feedback 1 DispScale
313
P3-13
PID1 WakeUpLevel
314
P3-14
Reserved Parameter
315
P3-15
Reserved Parameter
316
P3-16
Reserved Parameter
317
P3-17
Reserved Parameter
318
P3-18
PID1 ResetControl
401
P4-01
Motor Control Mode
402
P4-02
Motor Identification
403
P4-03
MSC Kp
404
P4-04
MSC Ti
405
P4-05
Motor PF
406
P4-06
M-Ref Source
407
P4-07
M-Max Motoring
408
P4-08
M-Min Motoring
409
P4-09
M-Max Generative
410
P4-10
f-MidV/f
411
P4-11
V-MidV/f
412
P4-12
T-Memory Enable
413
P4-13
Change Phasesequence Motor
46
Access
rw/ro
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
-
-
-
-
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Modbus RTU for variable frequency drive DA1, DC1, DE1 09/16 MN040018EN www.eaton.com
Scaling
RUN/
STOP
RUN
1 ≙ 0.1
RUN
1 ≙ 0.1
RUN
1 ≙ 0.01
RUN
RUN
1 ≙ 1
RUN
1 ≙ 0.1 %
RUN
1 ≙ 0.1 %
RUN
1 ≙ 0.1 %
RUN
RUN
RUN
1 ≙ 0.1 %
RUN
0: disabled
1 ≙ 0.001
RUN
1 ≙ 0.1 %
-
-
-
-
RUN
1 ≙ 1
STOP
STOP
RUN
1 ≙ 0.1 %
RUN
1 ≙ 0.001 s
RUN
99 ≙ 0.99
RUN
1 ≙ 1
RUN
2000 ≙ 200.0 %
RUN
1 ≙ 0.1 %
RUN
1 ≙ 1 %
STOP
1 ≙ 0.1 %
RUN
1 ≙ 0.1 %
RUN
1 ≙ 1
RUN
1 ≙ 1
Value range
Data
format
1 - 300
U16
0 - 300 s
U16
0.00 - 100 s
U16
0, 1
WORD
0, 1, 2
U16
0 - 1000
U16
P3-08 - 1000
U16
0- P3-07
U16
0, 1, 2, 3
U16
0, 1
WORD
0 - 250
U16
0.00 - 50.000
U16
0 - 1000
U16
0, 1
U16
0 - 6
U16
0, 1
WORD
1 - 4000
U16
1 - 1000
U16
• 0.00 (= disabled)
U16
• 0.50 - 0.99
0, 1, ..., 5
U16
0 - 2000
U16
0 - 150 %
U16
0 - 200 %
U16
0.0 - 100.0 %
U16
0.0 - 100.0 %
U16
0, 1
U16
0, 1
U16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerxl dc1Powerxl de1

Table of Contents